Changing from Automatic to Manual Mode

You can change from automatic mode to manual mode and back again.
Click manual in the control button area.
The current step of the automatic mode is executed until pausing is possible; this may take some time. Pausing is possible in one of these states:
  • At the beginning of a step
  • Before an action is executed
  • Before the control mode is changed
  • After the control mode has been changed
  • After a ramp has finished
  • Depending on the parameterization (ABTsub_Ramp_break.CTL) even while a ramp is active
  • While steady state time is active
  • While measurement time is active (measurement time is paused, but measurement is continued)
  • This behavior may be forbidden by setting the variable XXX_Break_during_measurement.ACT to 0.
  • While a condition for changing to next step is executed

The setpoint values of the current step are copied to the Set 2 column of the manual mode.

Manual mode is activated and you can manually change the desired settings.