LED Functionality
- 更新日2024-03-01
- 1分で読める
LED Functionality
The module includes two LED indicators per port to help you monitor hardware and bus status.
| LED Label | LED State | LED Color | Condition |
|---|---|---|---|
| LINK/ACT | Off | — |
No link established Default power-up state |
| Solid | Green | Link established, 100 Mb/s 1 This pattern only applies to the PXIe-8523.[1] | |
| Blinking | Green | Activity, 100 Mb/s [1] | |
| Solid | Amber | Link established, 1000 Mb/s | |
| Blinking | Amber | Activity, 1000 Mb/s | |
| STATUS | Off | — | Default power-up state |
| Solid | Green | Direct Mode, master (PHY state) | |
| Amber | Direct Mode, slave (PHY state) | ||
| Fade in and out[2]2 When in Tap Mode, ports that are paired fade in phase with each other, but out of phase with other ports. | Green | Tap Mode, master (PHY state) | |
| Amber | Tap Mode, slave (PHY state) | ||
| Blinking | Green | Port ID | |
| Amber | Not synchronized | ||
| Red | Catastrophic error[3]3 In the case of a catastrophic error, recover by invoking Reset on the module in MAX. Contact NI for further support if the error continues to occur. |
1 This pattern only applies to the PXIe-8523.
2 When in Tap Mode, ports that are paired fade in phase with each other, but out of phase with other ports.
3 In the case of a catastrophic error, recover by invoking Reset on the module in MAX. Contact NI for further support if the error continues to occur.