RFmxCDMA2k CDA Configure Measurement Channel VI
- Updated2025-10-13
- 3 minute(s) read
Configures the spreading factor, spreading code, modulation type, and branch of the channel to be measured.

Inputs/Outputs
Selector String
—
Selector String specifies a selector string comprising of the signal name. If you do not specify the signal name, the default signal instance is used. The default value is "" (empty string). Examples: "" "signal::sig1" You can use the RFmxCDMA2k Build Signal String VI to build the selector string.
Instrument Handle In
—
Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.
Walsh Code Length
—
Walsh Code Length specifies the Walsh code length of a channel subject to channel specific analysis. The default value is 64. The valid values are 2, 4, 8, 16, 32, and 64.
Walsh Code Number
—
Walsh Code Number specifies the Walsh code number of a channel subject to channel specific analysis.
Branch
—
Branch specifies the Walsh branch of a channel subject to channel specific analysis. The default value is I.
error in (no error)
—
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
Instrument Handle Out
—
Instrument Handle Out passes a reference to your RFmx session to the next VI.
error out
—
error out contains error information. This output provides standard error out functionality. |
Selector String
—
Instrument Handle In
—
Walsh Code Length
—
error in (no error)
—
Instrument Handle Out
—
error out
—