VeriStand .NET API Reference

Alarms.AddNewAlarm Method (String, String, Channel, ValueSource, ValueSource, Procedure, AlarmMode, AlarmState, UInt32, UInt32, Double, String)

Adds a new Alarm with the specified name, description, and configuration to the Alarms section. This method uses channels OR constants to specify the UpperLimit and LowerLimit values within which AlarmSource must stay to avoid triggering the alarm. This constructor also specifies the GroupNumber to which the alarm belongs.

Namespace: NationalInstruments.VeriStand.SystemDefinitionAPI
Assembly: NationalInstruments.VeriStand.SystemDefinitionAPI (in NationalInstruments.VeriStand.SystemDefinitionAPI.dll) Version: 2013.0.0.0 (2013.0.0.0)
Visual Basic (Declaration)
Public Function AddNewAlarm ( _
	Name As String, _
	Description As String, _
	AlarmSource As Channel, _
	UpperLimit As ValueSource, _
	LowerLimit As ValueSource, _
	AlarmAction As Procedure, _
	Mode As AlarmMode, _
	DefaultState As AlarmState, _
	GroupNumber As UInteger, _
	PriorityNumber As UInteger, _
	Delay As Double, _
	TripMessage As String _
) As Boolean
C#
public bool AddNewAlarm(
	string Name,
	string Description,
	Channel AlarmSource,
	ValueSource UpperLimit,
	ValueSource LowerLimit,
	Procedure AlarmAction,
	AlarmMode Mode,
	AlarmState DefaultState,
	uint GroupNumber,
	uint PriorityNumber,
	double Delay,
	string TripMessage
)
Visual C++
public:
bool AddNewAlarm(
	String^ Name, 
	String^ Description, 
	Channel^ AlarmSource, 
	ValueSource UpperLimit, 
	ValueSource LowerLimit, 
	Procedure^ AlarmAction, 
	AlarmMode Mode, 
	AlarmState DefaultState, 
	unsigned int GroupNumber, 
	unsigned int PriorityNumber, 
	double Delay, 
	String^ TripMessage
)

Parameters

Name
Type: System.String
The name of the Alarm.
Description
Type: System.String
The description of the Alarm.
AlarmSource
Type: NationalInstruments.VeriStand.SystemDefinitionAPI.Channel
The channel to monitor for alarm conditions.
UpperLimit
Type: NationalInstruments.VeriStand.SystemDefinitionAPI.ValueSource
The channel or constant that determines the high limit value of the alarm. If the value of AlarmSource exceeds this limit, the alarm is triggered.
LowerLimit
Type: NationalInstruments.VeriStand.SystemDefinitionAPI.ValueSource
The channel or constant that determines the low limit value of the alarm. If the value of AlarmSource falls below this limit, the alarm is triggered.
AlarmAction
Type: NationalInstruments.VeriStand.SystemDefinitionAPI.Procedure
The Procedure to initiate when the alarm occurs.
Mode
Type: NationalInstruments.VeriStand.SystemDefinitionAPI.AlarmMode
The AlarmMode.
DefaultState
Type: NationalInstruments.VeriStand.SystemDefinitionAPI.AlarmState
The default AlarmState.
GroupNumber
Type: System.UInt32
The number of the group to which the Alarm belongs.
PriorityNumber
Type: System.UInt32
The priority of the alarm. Lower numbers specify a higher alarm priority. For example, 4 is higher priority than 31.
Delay
Type: System.Double
The amount of time to wait before triggering the alarm.
TripMessage
Type: System.String
The message to display when the alarm is tripped.

Return Value

true (True in Visual Basic) if the Alarm was added successfully.

See Also