TRC-8546 Specifications
- Updated2025-06-30
- 4 minute(s) read
TRC-8546 Specifications
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted.
TRC-8546 Pinout
Use the pinout to connect to terminals on the TRC-8546.
| D-SUB Pin | Signal | Description |
|---|---|---|
| 1 | NC | No connection |
| 2 | NC | No connection |
| 3 | COM | LIN reference ground |
| 4 | NC | No connection |
| 5 | (SHLD) | Optional LIN shield |
| 6 | (COM) | Optional LIN reference ground |
| 7 | LIN | LIN data line |
| 8 | NC | No connection |
| 9 | VSUP | External power supply +8 V to +18 V) required |
LIN Characteristics
Transceiver | NXP TJA1028 |
Max certified baud rate | 20 kbps |
LIN bus lines voltage | -40 VDC to +40 VDC |
Supply voltage range (VSUP) | +8 VDC to +18 VDC normal operating; -0.3 VDC to +40 VDC absolute limits |
MTBF | Contact NI for Bellcore MTBF specifications at other temperatures or MIL-HDBK-217F specifications. |
Safety
Maximum Voltage[1]1 The maximum voltage that can be applied or output without creating a safety hazard.
Connect only the voltages that are within these limits.
Port-to-COM | -40 V DC to +40 V DC maximum, Measurement Category I |
Isolation Voltage
| |||||
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Environmental Characteristics
Refer to the manual for the host you are using for more information about meeting these specifications.
| |||||||
| |||||||
Ingress protection | IP40 | ||||||
Pollution Degree | 2 | ||||||
Maximum altitude | 5,000 m | ||||||
Shock and Vibration
To meet these specifications, you must securely mount the product and ensure all cables and connectors have proper strain relief.
| |||||||
Operating shock | 30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations | ||||||
Power Requirements
Thermal dissipation (at 70 °C) | 650 mW maximum (active mode); 330 mW typical (active mode) |
Power consumption from NI-XNET Transceiver Cable host | 330 mW maximum (active mode); 150 mW typical (active mode) |
Power consumption from VSUP | 320 mW maximum; 180 mW typical |
Physical Characteristics
Weight | 70 g (2.5 oz) |
Length | 447 mm to 462 mm (17.6 in. to 18.2 in.) |