TRC-8546 LEDs
- Updated2023-08-07
- 1 minute(s) read
TRC-8546 LEDs
The TRC-8546 includes two LEDs per port to help you monitor hardware and bus status. LED 1 primarily indicates whether the hardware is currently in use. LED 2 primarily indicates the activity information of the connected bus. Each LED can display two colors (red or green), which display in the following four patterns:
| Pattern | Meaning |
|---|---|
| Off | No LED illumination |
| Solid | LED fully illuminated |
| Blink | Blinks at a constant rate of several times per second |
| Activity | Blinks in a pseudo-random pattern |
| Condition/State | LED 1 | LED 2 |
|---|---|---|
| Port identification | Blinks green | Blinks green |
| NI-XNET catastrophic error | Blinks red | Blinks red |
| No open session on hardware | Off | Off |
| Open session on hardware, port is properly powered, and hardware is not communicating | Solid green | Off |
| Open session on hardware, port is missing power | Solid red | Off |
| Hardware is communicating | Solid green | Activity green (returns to idle/off one second after last TX or RX) |