TRC-8543 Specifications
- Updated2025-06-30
- 5 minute(s) read
TRC-8543 Specifications
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted.
TRC-8543 Pinout
Use the pinout to connect to terminals on the TRC-8543.
| Pin | Description |
|---|---|
| 1 | No Connection (NC) |
| 2 | CAN_L |
| 3 | COM |
| 4 | NC |
| 5 | NC |
| 6 | COM |
| 7 | CAN_H |
| 8 | NC |
| 9 | VSUP |
High-Speed/Flexible Data-Rate Signal Improvement Capability (SIC) CAN Characteristics
Transceiver | NXP TJA1463 |
Certified baud rate (maximum) | 8 Mb/s[1]1 NI-XNET provides a warning for CAN FD transceivers used at baud rates that exceed 5 Mb/s. These warnings can be safely ignored when using the NXP TJA1463 within its certified limits. The NXP TJA1463 transceiver is CiA certified for baud rates up to 8 Mb/s in the CAN FD fast phase. |
Input voltage limits CAN_H, CAN_L bus lines | -27 V DC to +40 V DC |
Output voltage limit CAN_H, CAN_L bus lines | 5 V DC |
MTBF | Contact NI for Bellcore MTBF specifications at other temperatures or MIL-HDBK-217F specifications. |
High-Speed/Flexible Data-Rate CAN Characteristics
Transceiver | NXP TJA1043T |
Certified baud rate (maximum) | 5 Mb/s [2]2 NI-XNET provides a warning for CAN FD transceivers used at baud rates that exceed 5 Mb/s. The NXP TJA1043T transceiver is CiA certified for baud rates up to 5 Mb/s in the CAN FD fast phase. |
Input voltage limits CAN_H, CAN_L bus lines | -27 V DC to +40 V DC |
Output voltage limit CAN_H, CAN_L bus lines | 5 V DC |
MTBF | Contact NI for Bellcore MTBF specifications at other temperatures or MIL-HDBK-217F specifications. |
Low-Speed/Fault-Tolerant CAN Characteristics
Transceiver | NXP TJA1055T |
Baud rate (maximum) | 125 Kb/s |
CAN_H, CAN_L bus lines voltage | -27 V DC to +40 V DC |
CAN Supply voltage range (VSUP) | +9 V DC to +30 V DC |
MTBF | Contact NI for Bellcore MTBF specifications at other temperatures or for MIL-HDBK-217F specifications. |
Power Requirements
Thermal dissipation (at 70 °C) | 700 mW maximum (Low-Speed/Fault-Tolerant fault condition) 550 mW maximum (High-Speed active mode) 440 mW typical (High-Speed active mode) 333 mW typical (Low-Speed/Fault-Tolerant active mode) |
Power consumption from TRC-8543 host | 550 mW maximum (High-Speed active mode) 440 mW typical (High-Speed active mode) 310 mW maximum (Low-Speed/Fault-Tolerant active mode) 245 mW typical (Low-Speed/Fault-Tolerant active mode) |
Power consumption from VSUP | 320 mW maximum (Low-Speed/Fault-Tolerant fault condition) 90 mW typical (Low-Speed/Fault-Tolerant active mode) |
Physical Characteristics
Weight | 70 g (2.5 oz) |
Length | 447 mm to 462 mm (17.6 in. to 18.2 in.) |
D-Sub connector jackscrew maximum torque | 0.56 N · m (5.0 lb · in.) |
Safety
Maximum Voltage[3]3 The maximum voltage that can be applied or output without creating a safety hazard.
Connect only the voltages that are within these limits.
Port-to-COM | -27 V DC to +40 V DC maximum, Measurement Category I |
Isolation Voltage
| |||||
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Environmental Characteristics
Refer to the manual for the host you are using for more information about meeting these specifications.
| |||||||
| |||||||
Ingress protection | IP40 | ||||||
Pollution Degree | 2 | ||||||
Maximum altitude | 5,000 m | ||||||
Shock and Vibration
To meet these specifications, you must securely mount the product and ensure all cables and connectors have proper strain relief.
| |||||||
Operating shock | 30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations | ||||||
1 NI-XNET provides a warning for CAN FD transceivers used at baud rates that exceed 5 Mb/s. These warnings can be safely ignored when using the NXP TJA1463 within its certified limits. The NXP TJA1463 transceiver is CiA certified for baud rates up to 8 Mb/s in the CAN FD fast phase.
2 NI-XNET provides a warning for CAN FD transceivers used at baud rates that exceed 5 Mb/s. The NXP TJA1043T transceiver is CiA certified for baud rates up to 5 Mb/s in the CAN FD fast phase.
3 The maximum voltage that can be applied or output without creating a safety hazard.
4 Similar to other standard PVC cables, this product’s cable becomes less ductile at low temperatures. Preroute and secure the cable while flexible to avoid premature failure.