Property Flags That Affect Reports
- Updated2025-07-23
- 1 minute(s) read
Set the PropFlags_IncludeInReport, PropFlags_IsLimit, and PropFlags_IsMeasurementValue flags to identify the result properties to automatically display in the report.
The PropFlags_IncludeInReport flag specifies to include a property in the report. For properties that hold limit values or output values, use the PropFlags_IsLimit and PropFlags_IsMeasurementValue flags to selectively exclude limits or output values according to the options you select in the Report Options dialog box. When you set a reporting flag for an array or container property, TestStand sets the flag for all array elements or subproperties within the container property.