Gets the hardware for acquisition, performs measurement on acquired data, and returns Spectrum measurement results.

Syntax

Namespace: NationalInstruments.RFmx.SpecAnMX

public int Read(string selectorString, double timeout, ref Spectrum< float > spectrum)

Remarks

This method maps to the RFmxSpecAn_SpectrumRead() function in C.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

timeoutdouble

Specifies the timeout, in seconds, for fetching the specified measurement. Set this value to an appropriate time longer than expected for fetching the measurement.

spectrumref Spectrum< float >

Upon return, contains the spectrum trace.

Returns

Returns the status code of this method. The status code either indicates success or describes an error or warning condition.