GetIFOutputPowerOffsetAuto(string, out RFmxSpecAnMXIMIFOutputPowerOffsetAuto)
- Updated2025-10-13
- 1 minute(s) read
Gets whether the measurement computes an IF output power level offset for the intermods to maximize the dynamic range of the signal analyzer. This method is used only if you set the SetMeasurementMethod(string, RFmxSpecAnMXIMMeasurementMethod) method to DynamicRange.
Syntax
Namespace: NationalInstruments.RFmx.SpecAnMX
public int GetIFOutputPowerOffsetAuto(string selectorString, out RFmxSpecAnMXIMIFOutputPowerOffsetAuto value)
Remarks
This method gets the value of IMIFOutputPowerOffsetAuto attribute.The default value is True.
Parameters
| Name | Type | Description |
|---|---|---|
| selectorString | string | Pass an empty string. The signal name that is passed when creating the signal configuration is used. |
| value | out RFmxSpecAnMXIMIFOutputPowerOffsetAuto | Upon return, contains whether the measurement computes an IF output power level offset for the intermods to maximize the dynamic range of the signal analyzer. This method is used only if you set the SetMeasurementMethod(string, RFmxSpecAnMXIMMeasurementMethod) method to DynamicRange. |
Returns
Returns the status code of this method. The status code either indicates success or describes a warning condition.