GetMeasurementMode(string, out RFmxSpecAnMXChpMeasurementMode)
- Updated2025-10-13
- 1 minute(s) read
Gets whether the measurement calibrates the noise floor of analyzer or performs the CHP measurement. Refer to the measurement guidelines section in the Noise Compensation Algorithm topic for more information.
Syntax
Namespace: NationalInstruments.RFmx.SpecAnMX
public int GetMeasurementMode(string selectorString, out RFmxSpecAnMXChpMeasurementMode value)
Remarks
This method gets the value of ChpMeasurementMode attribute.The default value is Measure.
Parameters
| Name | Type | Description |
|---|---|---|
| selectorString | string | Pass an empty string. The signal name that is passed when creating the signal configuration is used. |
| value | out RFmxSpecAnMXChpMeasurementMode | Upon return, contains whether the measurement calibrates the noise floor of analyzer or performs the CHP measurement. Refer to the measurement guidelines section in the Noise Compensation Algorithm topic for more information. |
Returns
Returns the status code of this method. The status code either indicates success or describes a warning condition.