Configures the duration, in seconds, of the reference waveform considered for the AMPM measurement. When the reference waveform contains an idle duration, the AMPM measurement neglects the idle samples in the reference waveform leading upto the start of the first active portion of the reference waveform.

Syntax

Namespace: NationalInstruments.RFmx.SpecAnMX

public int ConfigureMeasurementInterval(string selectorString, double measurementInterval)

Remarks

This method maps to the RFmxSpecAn_AMPMCfgMeasurementInterval() function in C.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

measurementIntervaldouble

Specifies the duration, in seconds, of the reference waveform considered for the AMPM measurement. When the reference waveform contains an idle duration, the AMPM measurement neglects the idle samples in the reference waveform leading upto the start of the first active portion of the reference waveform.

Returns

Returns the status code of this method. The status code either indicates success or describes an error or warning condition.