DPD
- Updated2025-10-13
- 2 minute(s) read
Groups
Group members
| Name | Description |
|---|---|
| RFMXSPECAN_ATTR_DPD_ALL_TRACES_ENABLED | Specifies whether to enable the traces to be stored and retrieved after performing the DPD measurement. |
| RFMXSPECAN_ATTR_DPD_DUT_AVERAGE_INPUT_POWER | Specifies the average power of the signal at the device under test input port. This value is expressed in dBm. |
| RFMXSPECAN_ATTR_DPD_FREQUENCY_OFFSET_CORRECTION_ENABLED | Specifies whether to enable frequency offset correction for the DPD measurement. |
| RFMXSPECAN_ATTR_DPD_IQ_ORIGIN_OFFSET_CORRECTION_ENABLED | Enables the IQ origin offset correction for the measurement. |
| RFMXSPECAN_ATTR_DPD_ITERATIVE_DPD_ENABLED | Specifies whether to enable iterative computation of the DPD Results DPD Polynomial using DPD. |
| RFMXSPECAN_ATTR_DPD_MAXIMUM_TIMING_ERROR | Specifies the maximum time alignment error expected between the acquired and the reference waveforms. This value is expressed in seconds. |
| RFMXSPECAN_ATTR_DPD_MEASUREMENT_ENABLED | Specifies whether to enable DPD measurement. |
| RFMXSPECAN_ATTR_DPD_MEASUREMENT_INTERVAL | Specifies the duration of the reference waveform considered for the DPD measurement. When the reference waveform contains an idle duration, the DPD measurement neglects the idle samples in the reference waveform leading up to the start of the first active portion of the reference waveform. This value is expressed in seconds. |
| RFMXSPECAN_ATTR_DPD_MEASUREMENT_MODE | Specifies if the training waveform required for the extraction of the DPD model coefficients is acquired from the hardware or is configured by the user. |
| RFMXSPECAN_ATTR_DPD_MODEL | Specifies the DPD model used by the DPD measurement. |
| RFMXSPECAN_ATTR_DPD_NMSE_ENABLED | Specifies whether to enable the normalized mean-squared error (NMSE) computation. |
| RFMXSPECAN_ATTR_DPD_NUMBER_OF_ANALYSIS_THREADS | Specifies the maximum number of threads used for parallelism of the DPD measurement. |
| RFMXSPECAN_ATTR_DPD_SIGNAL_TYPE | Specifies whether the reference waveform is a modulated signal or a combination of one or more sinusoidal signals. To time-align the sinusoidal reference waveform to the acquired signal, set the DPD Signal Type attribute to Tones, which switches the DPD measurement alignment algorithm. |
| RFMXSPECAN_ATTR_DPD_SYNCHRONIZATION_METHOD | Specifies the method used for synchronization of the acquired waveform with the reference waveform. |
| RFMXSPECAN_ATTR_DPD_TARGET_GAIN_TYPE | Specifies the gain expected from the DUT after applying DPD on the input waveform. |
Attachments
None