Groups

Group members

NameDescription
RFMXSPECAN_ATTR_DPD_ALL_TRACES_ENABLED

Specifies whether to enable the traces to be stored and retrieved after performing the DPD measurement.

RFMXSPECAN_ATTR_DPD_DUT_AVERAGE_INPUT_POWER

Specifies the average power of the signal at the device under test input port. This value is expressed in dBm.

RFMXSPECAN_ATTR_DPD_FREQUENCY_OFFSET_CORRECTION_ENABLED

Specifies whether to enable frequency offset correction for the DPD measurement.

RFMXSPECAN_ATTR_DPD_IQ_ORIGIN_OFFSET_CORRECTION_ENABLED

Enables the IQ origin offset correction for the measurement.

RFMXSPECAN_ATTR_DPD_ITERATIVE_DPD_ENABLED

Specifies whether to enable iterative computation of the DPD Results DPD Polynomial using DPD.

RFMXSPECAN_ATTR_DPD_MAXIMUM_TIMING_ERROR

Specifies the maximum time alignment error expected between the acquired and the reference waveforms. This value is expressed in seconds.

RFMXSPECAN_ATTR_DPD_MEASUREMENT_ENABLED

Specifies whether to enable DPD measurement.

RFMXSPECAN_ATTR_DPD_MEASUREMENT_INTERVAL

Specifies the duration of the reference waveform considered for the DPD measurement. When the reference waveform contains an idle duration, the DPD measurement neglects the idle samples in the reference waveform leading up to the start of the first active portion of the reference waveform. This value is expressed in seconds.

RFMXSPECAN_ATTR_DPD_MEASUREMENT_MODE

Specifies if the training waveform required for the extraction of the DPD model coefficients is acquired from the hardware or is configured by the user.

RFMXSPECAN_ATTR_DPD_MODEL

Specifies the DPD model used by the DPD measurement.

RFMXSPECAN_ATTR_DPD_NMSE_ENABLED

Specifies whether to enable the normalized mean-squared error (NMSE) computation.

RFMXSPECAN_ATTR_DPD_NUMBER_OF_ANALYSIS_THREADS

Specifies the maximum number of threads used for parallelism of the DPD measurement.

RFMXSPECAN_ATTR_DPD_SIGNAL_TYPE

Specifies whether the reference waveform is a modulated signal or a combination of one or more sinusoidal signals. To time-align the sinusoidal reference waveform to the acquired signal, set the DPD Signal Type attribute to Tones, which switches the DPD measurement alignment algorithm.

RFMXSPECAN_ATTR_DPD_SYNCHRONIZATION_METHOD

Specifies the method used for synchronization of the acquired waveform with the reference waveform.

RFMXSPECAN_ATTR_DPD_TARGET_GAIN_TYPE

Specifies the gain expected from the DUT after applying DPD on the input waveform.

Attachments

None