Specifies the maximum number of threads used for parallelism of the DPD measurement.

Syntax

RFMXSPECAN_ATTR_DPD_NUMBER_OF_ANALYSIS_THREADS

Numeric Value

Data Type

Access

Applies To

1110048

int32

Read/Write

N/A

Remarks


The number of threads can range from 1 to the number of physical cores. However, the number of threads you set may not all be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is 1.