RFmxNR SEM Fetch Lower Offset Power (Array) VI
- Updated2025-10-13
- 3 minute(s) read
Returns an array of total absolute and relative powers, peak, absolute, and relative powers, and frequencies at peak absolute powers of lower offset segments. The relative power is relative to total aggregated power.
Use "subblock<n>" as the selector string to read results from this VI.

Inputs/Outputs
Selector String
—
Selector String specifies a selector string comprising of the signal name, result name, and subblock number. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "" (empty string). Example: "subblock0" "signal::sig1/subblock0" "result::r1/subblock0" "signal::sig1/result::r1/subblock0" You can use the RFmxNR Build Subblock String VI to build the selector string.
Instrument Handle In
—
Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.
Timeout (s)
—
Timeout specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.
error in (no error)
—
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
Peak Relative Power (dB)
—
Peak Relative Power returns an array of the peak power in the lower offset segment relative to total aggregated power. This value is expressed in dB.
Peak Frequency (Hz)
—
Peak Frequency returns an array of the frequency at which the peak power occurs in the lower offset segment. This value is expressed in Hz.
Instrument Handle Out
—
Instrument Handle Out passes a reference of your RFmx session to the next VI.
Total Absolute Power (dBm)
—
Total Absolute Power returns an array of the lower (negative) segment power. This value is expressed in dBm.
Total Relative Power (dB)
—
Total Relative Power returns an array of the power in the lower offset segment relative to total aggregated power. This value is expressed in dB.
Peak Absolute Power (dBm)
—
Peak Absolute Power returns an array of the peak power in the lower offset segment. This value is expressed in dBm.
error out
—
error out contains error information. This output provides standard error out functionality. |
Selector String
—
Instrument Handle In
—
Timeout (s)
—
error in (no error)
—
Peak Relative Power (dB)
—
Instrument Handle Out
—
error out
—