RFmxNR SEM Configure Offset Bandwidth Integral (Array) VI
- Updated2025-10-13
- 2 minute(s) read
Configures an array of the bandwidth integral of the offset segments.
Use "subblock<n>" as the selector string to configure or read this property.

Inputs/Outputs
Selector String
—
Selector String specifies a selector string comprising of the signal name and the subblock number. If you do not specify the signal name, the default signal instance is used. The default value is "subblock0". Example: "subblock0" "signal::sig1/subblock0" You can use the RFmxNR Build Signal String VI to build the selector string.
Instrument Handle In
—
Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.
Bandwidth Integral
—
Bandwidth Integral specifies an array of the resolution of a spectrum to compare with the spectral mask limits as an integer multiple of the RBW. When you set this parameter to a value greater than 1, the measurement acquires the spectrum with a narrow resolution and then processes it digitally to get a wider resolution that is equal to the product of a bandwidth integral and a RBW. The default value is 1.
error in (no error)
—
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
Instrument Handle Out
—
Instrument Handle Out passes a reference of your RFmx session to the next VI.
error out
—
error out contains error information. This output provides standard error out functionality. |
Selector String
—
Instrument Handle In
—
Bandwidth Integral
—
error in (no error)
—
Instrument Handle Out
—
error out
—