Fetches an array of the maximum value across averaging counts of the frequency error per slot for all slots within the measurement length. This value is expressed in Hz.
Use "carrier<k>" or "subblock<n>" or "subblock<n>/carrier<k>" or "subblock<n>/carrier<k>/layer<q>" as the selector string to read this result.

Inputs/Outputs
Selector String
—
Selector String specifies a selector string comprising of the signal name, result name, subblock number, carrier number and layer number. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "subblock0/carrier0/layer0". Example: "subblock0/carrier0/layer0" "signal::sig1/subblock0/carrier0/layer0" "result::r1/subblock0/carrier0/layer0" "signal::sig1/result::r1/subblock0/carrier0/layer0" You can use the RFmxNR Build Carrier String and RFmxNR Build Layer String VIs to build the selector string.
Instrument Handle In
—
Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.
Timeout (s)
—
Timeout specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.
error in (no error)
—
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
Instrument Handle Out
—
Instrument Handle Out passes a reference of your RFmx session to the next VI.
Frequency Error per Slot Maximum (Hz)
—
Frequency Error per Slot Maximum returns an array of the maximum value across averaging counts of the frequency error per slot for all slots within the measurement length. This value is expressed in Hz.
error out
—
error out contains error information. This output provides standard error out functionality. |
Selector String
—
Instrument Handle In
—
Timeout (s)
—
error in (no error)
—
Instrument Handle Out
—
Frequency Error per Slot Maximum (Hz)
—
x0
—
y
—
error out
—