Fetches an array of the maximum value across averaging counts of the frequency error per slot for all slots within the measurement length. This value is expressed in Hz.

Use "carrier<k>" or "subblock<n>" or "subblock<n>/carrier<k>" or "subblock<n>/carrier<k>/layer<q>" as the selector string to read this result.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name, result name, subblock number, carrier number and layer number. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "subblock0/carrier0/layer0".

    Example:

    "subblock0/carrier0/layer0"

    "signal::sig1/subblock0/carrier0/layer0"

    "result::r1/subblock0/carrier0/layer0"

    "signal::sig1/result::r1/subblock0/carrier0/layer0"

    You can use the RFmxNR Build Carrier String and RFmxNR Build Layer String VIs to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • cdbl.png Timeout (s)

    Timeout specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference of your RFmx session to the next VI.

  • icclst.png Frequency Error per Slot Maximum (Hz)

    Frequency Error per Slot Maximum returns an array of the maximum value across averaging counts of the frequency error per slot for all slots within the measurement length. This value is expressed in Hz.

  • idbl.png x0

    x0 returns the index of the first active slot.

  • idbl.png dx

    dx returns the increment value. This is always set to one slot.

  • i1dsgl.png y

    y returns an array of the maximum value across averaging counts of the frequency error per slot for all slots within the measurement length.

  • ierrcodeclst.png error out