Specifies whether same reference clock is used for local oscillator and digital-to-analog converter. When same reference clock is used the Carrier Frequency Offset is proportional to Sample Clock Error.

You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is True.

Remarks

The following table lists the characteristics of this property.

Short Name ModAcc Common Clock Source Enabled
Data type ci32.png
Permissions Read/Write
High-level VIs N/A
Resettable Yes
False 0

The Sample Clock error is estimated independently.

True 1

The Sample Clock error is estimated from carrier frequency offset.