Specifies the units in which measurement offset and measurement length are specified.

You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

The default value is Slot.

Remarks

The following table lists the characteristics of this property.

Short Name ModAcc Meas Length Unit
Data type ci32.png
Permissions Read/Write
High-level VIs N/A
Resettable Yes
Slot 1

Measurement offset and measurement length are specified in units of slots.

Subframe 3

Measurement offset and measurement length are specified in units of subframes.

Time 6

Measurement offset and measurement length are specified in seconds. Specify the measurement offset and length in multiples of 1 ms * (15 kHz/minimum subcarrier spacing of all carriers). All slots within this notional time duration are analysed.