Classes

NameDescription
RFmxGsmMX

Defines a root class which is used to identify and control GSM signal configuration.

RFmxGsmMXConstants

Specifies constants for I/O terminals.

RFmxGsmMXModAcc

Represents the ModAcc measurement.

RFmxGsmMXModAccConfiguration

Provides methods to configure the ModAcc measurement.

RFmxGsmMXModAccResults

Provides methods to fetch and read the ModAcc measurement results.

RFmxGsmMXOrfs

Represents the ORFS measurement.

RFmxGsmMXOrfsConfiguration

Provides methods to configure the ORFS measurement.

RFmxGsmMXOrfsResults

Provides methods to fetch and read the ORFS measurement results.

RFmxGsmMXPvt

Represents the PVT measurement.

RFmxGsmMXPvtConfiguration

Provides methods to configure the PVT measurement.

RFmxGsmMXPvtResults

Provides methods to fetch and read the PVT measurement results.

RFmxGsmMXSubObject

Represents members that are common to all sub-object of RFmxGsmMX classes.

Interfaces

None

Structures

None

Enumerations

NameDescription
RFmxGsmMXAutoTscDetectionEnabled

Specifies whether the measurement automatically detects the training sequence code (TSC).

RFmxGsmMXBand

Specifies the operation band.

RFmxGsmMXBurstSynchronizationType

Specifies the method used to synchronize the burst.

RFmxGsmMXBurstType

Specifies the burst type. Use "slot(n)" as the selector string to configure or read this method.

RFmxGsmMXDigitalEdgeTriggerEdge

Specifies the active edge for the trigger. This method is used only when you set the SetTriggerType(string, RFmxGsmMXTriggerType) method to DigitalEdge.

RFmxGsmMXHBFilterWidth

Specifies the filter width when you set the SetBurstType(string, RFmxGsmMXBurstType) method to HB. Use "slot(n)" as the selector string to configure or read this method.

RFmxGsmMXIQPowerEdgeTriggerLevelType

Specifies the reference for the SetIQPowerEdgeTriggerLevel(string, double) method. The IQ Power Edge Level Type method is used only when you set the SetTriggerType(string, RFmxGsmMXTriggerType) method to IQPowerEdge.

RFmxGsmMXIQPowerEdgeTriggerSlope

Specifies whether the device asserts the trigger when the signal power is rising or when it is falling. The device asserts the trigger when the signal power exceeds the level that you specify in the SetIQPowerEdgeTriggerLevel(string, double) method with the slope you specify. This method is used only when you set the SetTriggerType(string, RFmxGsmMXTriggerType) method to IQPowerEdge.

RFmxGsmMXLimitedConfigurationChange

Specifies the set of properties that are considered by RFmx in the locked signal configuration state.

RFmxGsmMXLinkDirection

Specifies the direction for which the frequency is calculated. Only Uplink is supported.

RFmxGsmMXMeasurementTypes

Specifies the type of measurement.

RFmxGsmMXModAccAveragingEnabled

Specifies whether to enable averaging for the modulation accuracy (ModAcc) measurement.

RFmxGsmMXModAccDetectedTsc

Returns the detected training sequence code (TSC) if you set the SetBurstSynchronizationType(string, RFmxGsmMXBurstSynchronizationType) method to Tsc. Use "slot(n)" as the selector string to read this result. When the SetMeasurementInterval(string, RFmxGsmMXModAccMeasurementInterval) method is set to TimeslotAtOffset, Detected TSC array has one element and the Detected TSC is returned at index 0.

RFmxGsmMXModAccDroopCompensationEnabled

Specifies whether to enable droop compensation for the modulation accuracy (ModAcc) measurement. Droop compensation allows the ModAcc measurement to minimize the contribution of amplifier power variations to the EVM results.

RFmxGsmMXModAccMeasurementInterval

Specifies whether the measurement is performed on a single specified timeslot or across multiple timeslots.

RFmxGsmMXModulationType

Specifies the modulation scheme used for the signal. Use "slot(n)" as the selector string to configure or read this method.

RFmxGsmMXOrfsAveragingEnabled

Specifies whether to enable averaging for the output radio frequency spectrum (ORFS) measurement.

RFmxGsmMXOrfsAveragingType

Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the output radio frequency spectrum (ORFS) measurement.

RFmxGsmMXOrfsEvaluationSymbolsIncludeTsc

Specifies whether to include the training sequence code (TSC) portion of the burst in the output radio frequency spectrum (ORFS) measurement.

RFmxGsmMXOrfsEvaluationSymbolsScope

Specifies the modulation power measurements that will use the part of burst configured using the ConfigureEvaluationSymbols(string, double, RFmxGsmMXOrfsEvaluationSymbolsIncludeTsc, double) method.

RFmxGsmMXOrfsMeasurementInterval

Specifies whether the measurement is performed on a single specified timeslot or across multiple timeslots.

RFmxGsmMXOrfsMeasurementType

Specifies the type of spectral distortion to be measured.

RFmxGsmMXOrfsNoiseCompensationEnabled

Specifies whether to enable compensation of the channel powers for the inherent noise floor of the signal analyzer. Noise compensation is applicable only on modulation offsets and not on switching offsets. Supported Devices: PXIe-5663/5665/5668R, PXIe-5830/5831/5832.

RFmxGsmMXOrfsOffsetFrequencyMode

Specifies the list of frequency offsets for which you can perform the output radio frequency spectrum (ORFS) measurements.

RFmxGsmMXPropertyId

Specifies all the attribute identifiers.

RFmxGsmMXPvtAveragingEnabled

Specifies whether to enable averaging for the power versus time (PVT) measurement.

RFmxGsmMXPvtAveragingType

Specifies the averaging type for multiple acquisitions.

RFmxGsmMXPvtMeasurementStatus

Indicates the overall measurement status based on standard-defined limits.

RFmxGsmMXPvtSlotMeasurementStatus

Indicates the power versus time (PVT) measurement status for a particular slot. Use "slot(n)" as the selector string to read this method.

RFmxGsmMXSignalStructure

Specifies whether the signal is bursted or continuous. For bursted signal and continuous signals, set the SetTriggerType(string, RFmxGsmMXTriggerType) to IQPowerEdge and None, respectively.

RFmxGsmMXTriggerMinimumQuietTimeMode

Specifies whether the measurement computes the minimum quiet time used for triggering.

RFmxGsmMXTriggerType

Specifies the trigger type.

RFmxGsmMXTsc

Specifies the training sequence code (TSC) to use. This method is applicable only when you set the SetBurstSynchronizationType(string, RFmxGsmMXBurstSynchronizationType) method to Tsc and the SetAutoTscDetectionEnabled(string, RFmxGsmMXAutoTscDetectionEnabled) method to False. For access burst Tsc0, Tsc1, and Tsc2 are applicable. Use "slot(n)" as the selector string to configure or read this method.

Delegates

None