Fetches the overall PVT measurement status based on the standard defined measurement limits.

Syntax

Namespace: NationalInstruments.RFmx.GsmMX

public int FetchMeasurementStatus(string selectorString, double timeout, out RFmxGsmMXPvtMeasurementStatus measurementStatus)

Parameters

NameTypeDescription
selectorStringstring

Specifies a selector string comprising of the result name. If you do not specify the result name, the default result instance is used. The default is "" (empty string).
Example:
""
"result::r1"
You can use the BuildResultString(string) method to build the selector string.

timeoutdouble

Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete.

measurementStatusout RFmxGsmMXPvtMeasurementStatus

Indicates the overall measurement status based on standard-defined limits.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.