RFmxEVDO Send Software Edge Trigger VI
- Updated2025-10-13
- 2 minute(s) read
Sends a trigger to the device when you use the RFmxEVDO Configure Trigger VI to choose a software version of a trigger and the device is waiting for the trigger to be sent. You can also use this VI to override a hardware trigger.
This VI returns an error in the following situations:
- You configure an invalid trigger.
- You have not previously called the RFmxEVDO Initiate VI.

Inputs/Outputs
Instrument Handle In
—
Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.
error in (no error)
—
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
Instrument Handle Out
—
Instrument Handle Out passes a reference to your RFmx session to the next VI.
error out
—
error out contains error information. This output provides standard error out functionality. |
Instrument Handle In
—
error in (no error)
—
Instrument Handle Out
—
error out
—