Configures a user defined channel in the EV-DO uplink specified by the selector string. Use "channel<n>" as the selector string to configure this VI.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name and channel number. If you do not specify the signal name, the default signal instance is used. The default value is "channel0".

    Examples:

    "channel0"

    "signal::sig1/channel0"

    You can use the RFmxEVDO Build Channel String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • ci32.png Uplink Walsh Code Length
  • ci32.png Uplink Walsh Code Number
  • ci32.png Uplink Branch
    I(0) Specifies the in-phase component.
    Q(1) Specifies the quadrature component.
    I and Q(2) Specifies both the in-phase component and the quadrature component.
  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • ierrcodeclst.png error out