RFmxCDMA2k CDA Fetch Code Domain Power VI
- Updated2025-10-13
- 4 minute(s) read
Returns the scalar code domain power results.

Inputs/Outputs
Selector String
—
Selector String specifies a selector string comprising of the signal name and result name. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "" (empty string). Examples: "" "signal::sig1" "result::r1" "signal::sig1/result::r1" You can use the RFmxCDMA2k Build Signal String VI to build the selector string.
Instrument Handle In
—
Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.
Timeout (s)
—
Timeout specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.
error in (no error)
—
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
Mean Inactive Power (dB or dBm)
—
Mean Inactive Power returns the average code power measured among the set of inactive channels in the code domain of the base spreading factor. If you set the CDA Pwr Unit property to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power property.
Peak Active Power (dB or dBm)
—
Peak Active Power returns the maximum power among all active code channels. If you set the CDA Pwr Unit property to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power property.
Instrument Handle Out
—
Instrument Handle Out passes a reference to your RFmx session to the next VI.
Total Power (dBm)
—
Total Power returns the mean power of the received signal. This value is expressed in dBm.
Total Active Power (dB or dBm)
—
Total Active Power returns the sum of the powers of all active code channels. If you set the CDA Pwr Unit property to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power property.
Mean Active Power (dB or dBm)
—
Mean Active Power returns the average power of all active code channels. If you set the CDA Pwr Unit property to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power property.
error out
—
error out contains error information. This output provides standard error out functionality.
Peak Inactive Power (dB or dBm)
—
Peak Inactive Power returns the maximum measured code power among the set of inactive channels in the code domain of the base spreading factor. If you set the CDA Pwr Unit property to dBm, this measurement returns the absolute measured power; otherwise, this measurement returns a value relative to the CDA Result Total Power property. |
Selector String
—
Instrument Handle In
—
Timeout (s)
—
error in (no error)
—
Mean Inactive Power (dB or dBm)
—
Instrument Handle Out
—
error out
—