Returns the absolute and relative powers measured in the offset channel. The relative powers are measured relative to the carrier absolute power.

Syntax

Namespace: NationalInstruments.RFmx.Cdma2kMX

public int FetchOffsetMeasurementArray(string selectorString, double timeout, ref double[] lowerRelativePower, ref double[] upperRelativePower, ref double[] lowerAbsolutePower, ref double[] upperAbsolutePower)

Parameters

NameTypeDescription
selectorStringstring

Specifies a selector string comprising of the result name. If you do not specify the result name, the default result instance is used.

timeoutdouble

Specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the method waits until the measurement is complete.

lowerRelativePowerref double[]

Upon return, contains the array of lower offset channel powers measured relative to the carrier absolute power. This value is expressed in dB.

upperRelativePowerref double[]

Upon return, contains the array of upper offset channel powers measured relative to the carrier absolute power. This value is expressed in dB.

lowerAbsolutePowerref double[]

Upon return, contains the array of lower offset channel absolute powers.

upperAbsolutePowerref double[]

Upon return, contains the array of upper offset channel absolute powers.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.