Fetches the DEVM values for symbols from the enhanced data rate (EDR) portion of the EDR packet. This VI is valid only for EDR packets.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name and the result name. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "" (empty string).

    Example:

    "signal::sig1"

    "result::r1"

    "signal::sig1/result::r1"

    You can use the RFmxBT Build Signal String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • cdbl.png Timeout (s)

    Timeout specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • i1dsgl.png DEVM Per Symbol (%)

    DEVM Per Symbol returns the array of DEVM values computed over the symbols in the EDR portion of EDR packet. This value is expressed in percentage.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.