PXIe-8820 Specifications
- Updated2025-01-12
- 7 minute(s) read
PXIe-8820 Specifications
Features
| CPU | Intel® Celeron® 1020E (2.20 GHz dual-core processor) |
|---|---|
| On-die L2 cache | 2 MB |
| Single-Channel DDR3 RAM, PC3 10600 | 2 GB standard, 8 GB maximum |
| Hard Drive | 250 GB Serial ATA, minimum* |
| Ethernet | 10/100/1000 BaseT |
| PXI Express 4 Link Configuration | x1, x1, x1, x1 |
| PXI Express 2 Link Configuration | x1, x1 |
| Serial Port (RS-232) | Yes (1) |
| Parallel Port | Yes (1) |
| Hi-Speed USB (2.0) Ports | Yes (4) |
| PS/2 Keyboard/Mouse Connector | No |
| PXI Trigger Bus Input/Output | Yes |
| Installed Operating System | Windows 7 Professional |
| * Controllers configured for LabVIEW RT provide an 80 GB (minimum) SATA hard drive. | |
PXIe-8820 Pinout
This section details the Front Panel pinout for the PXIe-8820.
DisplayPort (DP)
| Pin | Signal Name |
|---|---|
| 1 | ML_Lane0(p) |
| 2 | GND |
| 3 | ML_Lane0(n) |
| 4 | ML_Lane1(p) |
| 5 | GND |
| 6 | ML_Lane1(n) |
| 7 | ML_Lane2(p) |
| 8 | GND |
| 9 | ML_Lane2(n) |
| 10 | ML_Lane3(p) |
| 11 | GND |
| 12 | ML_Lane3(n) |
| 13 | CONFIG1 |
| 14 | CONFIG2 |
| 15 | AUX CH (p) |
| 16 | GND |
| 17 | AUX CH (n) |
| 18 | Hot Plug Detect |
| 19 | Return |
| 20 | DP_PWR |
COM1 Pinout
| Pin | Signal Name | Signal Description |
|---|---|---|
| 1 | DCD# | Data Carrier Detect |
| 2 | RXD# | Receive Data |
| 3 | TXD# | Transmit Data |
| 4 | DTR# | Data Terminal Ready |
| 5 | GND | Ground |
| 6 | DSR# | Data Set Ready |
| 7 | RTS# | Ready to Send |
| 8 | CTS# | Clear to Send |
| 9 | RI# | Ring Indicator |
Ethernet Pinout
| Pin | Fast Ethernet | Gigabit Ethernet |
|---|---|---|
| 1 | TX+ | TX_A+ |
| 2 | TX– | TX_A- |
| 3 | RX+ | RX_B+ |
| 4 | NC | TX_C+ |
| 5 | NC | TX_C- |
| 6 | RX- | RX_B- |
| 7 | NC | RX_D+ |
| 8 | NC | RX_D-– |
Paralell Port Pinout
| Pin | Default Configuration (LPT) | |
|---|---|---|
| Signal Name | Signal Description | |
| 1 | BUSY | Device Busy |
| 2 | SLCT | Select |
| 3 | ACK# | Acknowledge |
| 4 | FAULT#(ERROR#) | Fault |
| 5 | PAPEREND | Paper End |
| 6 | PD0 | Data Bit 0 |
| 7 | PD1 | Data Bit 1 |
| 8 | PD2 | Data Bit 2 |
| 9 | PD3 | Data Bit 3 |
| 10 | PD4 | Data Bit 4 |
| 11 | PD5 | Data Bit 5 |
| 12 | PD6 | Data Bit 6 |
| 13 | PD7 | Data Bit 7 |
| 14 | INIT# | Initialize Printer |
| 15 | STROBE# | Strobe |
| 16 | SLCTIN# | Select Input |
| 17 | AUTOFD# | Auto Line Feed |
| 18 | +5V | +5V |
| 19-35 | GND | Ground |
| 36 | NC | Not Connected |
USB Pinout
| Pin | Signal Name | Signal Description |
|---|---|---|
| 1 | VCC | Cable Power (+5V) |
| 2 | -Data | USB Data - |
| 3 | +Data | USB Data + |
| 4 | GND | Ground |
Trigger (TRIG) Pinout
| Pin | Signal Name | Signal Description |
|---|---|---|
| 1 | TRIG | Trigger |
| 2 (Shield) | GND | Ground |
Front Panel Dimensions
The following figure shows the front panel layout and dimensions of the PXIe-8820. Dimensions are in inches (millimeters).
Electrical
| Voltage (V) | Current (Amps) Typical | Current (Amps) Maximum |
|---|---|---|
| +3.3 V | 1.9 A | 2.4 A |
| +5 V | 0.7 A | 1.9 A |
| +12 V | 2.3 A | 2.5 A |
| -12 V | 0 A | 0 A |
| +5 VAux | 0.55 A | 0.66 A |
Physical
Board dimensions | 2-slot 3U PXI Express module |
Slot requirements | One system slot plus one controller expansion slot |
Compatibility | Fully compatible with PXI Express Specification 1.0 |
Weight | 0.85 kg (1.87 lb) typical |
Environmental
Maximum altitude | 2,000 m (800 mbar) (at 25 °C ambient) |
Pollution Degree | 2 |
Indoor use only.
Operating Environment
Ambient temperature range | 5 °C to 50 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2. Meets MIL-PRF-28800F Class 3 high temperature limit.) |
Relative humidity range | 10% to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) |
Storage Environment
Ambient temperature range | -40 °C to 65 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2. Meets MIL-PRF-28800F Class 3 low temperature limit.) |
Relative humidity range | 5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.) |
Shock and Vibration
Operating shock | 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Meets MIL-PRF-28800F Class 2 limits.) | ||||||
| |||||||
Safety
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA C22.2 No. 61010-1
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- EN 55022 (CISPR 22): Class A emissions
- EN 55024 (CISPR 24): Immunity
- AS/NZS CISPR 11: Group 1, Class A emissions
- AS/NZS CISPR 22: Class A emissions
- FCC 47 CFR Part 15B: Class A emissions
- ICES-001: Class A emissions
CE Compliance

This product meets the essential requirements of applicable European Directives, as follows:
- 2014/35/EU; Low-Voltage Directive (safety)
- 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
- 2011/65/EU; Restriction of Hazardous Substances (RoHS)
- 2014/53/EU; Radio Equipment Directive (RED)
- 2014/34/EU; Potentially Explosive Atmospheres (ATEX)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.
EU and UK Customers
Battery Replacement and Disposal
电子信息产品污染控制管理办法(中国RoHS)
373989A-01