1. Call the niFgen Configure Trigger Mode VI or the niFgen_configureTriggerMode function to select the trigger mode in which your trigger will generate.
    This mode affects the behavior of the trigger and depends on the output mode of the signal generator.
  2. Call the niFgen Configure Trigger poly VI and choose the instance that corresponds to the type of trigger you want to use, or call one of the following niFgen Configure Trigger functions:
    • niFgen_ConfigureDigitalEdgeStartTrigger
    • niFgen_ConfigureSoftwareEdgeStartTrigger
    • niFgen_ConfigureDigitalEdgeScriptTrigger
    • niFgen_ConfigureDigitalLevelScriptTrigger
    • niFgen_ConfigureSoftwareEdgeScriptTrigger