PXIe-2526 Specifications

This document lists specifications for the PXIe-2526 . All specifications are subject to change without notice.

Topology
  • 1-wire 158×1 multiplexer
  • 2-wire 79×1 multiplexer

Definitions

Warranted Specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

  • Typical—describes the performance met by a majority of models.
  • Nominal—describes an attribute that is based on design, conformance testing, or supplemental testing.
  • Values are Typical unless otherwise noted.

    Conditions

    Specifications are valid at 23 °C unless otherwise noted.

    All voltages are specified in DC, ACpk, or a combination unless otherwise specified.

    PXIe-2526 Pinout

    The following figures show the PXIe-2526 connector pinouts.

    Figure 1. PXIe-2526 1-Wire Pinout


    Figure 2. PXIe-2526 2-Wire Pinout


    The following figure shows the PXIe-2526 power-on state.

    Figure 3. PXIe-2526 Power-On State


    Input Characteristics

    Maximum switching voltage, channel-to-channel 150 V
    Maximum switching voltage, channel-to-ground 150 V, CAT O
    Note This module is rated for Measurement Category I. It is intended to carry signal voltages no greater than 150 V. This module can withstand up to 800 V impulse voltage. Do not use this module for connection to signals or for measurements within Categories II, III, or IV. Do not connect to MAINS supply circuits (for example, wall outlets) of 115 VAC or 230 VAC.

    Measurement Categories CAT I and CAT O (Other) are equivalent and are for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. This category is for measurement of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special hardware, limited-energy parts of hardware, circuits powered by regulated low-voltage sources, and electronics.

    Caution When hazardous voltages (>42.4 Vpk/60 V DC) are present on any channel, safety low-voltage (≤42.4 Vpk/60 V DC) cannot be connected to any other channel.
    Maximum switching power 60 W, 62.5 VA
    Caution The switching power is limited by the maximum switching current, the maximum voltage, and must not exceed 60 W, 62.5 VA.
    CH-COM DC isolation resistance >1 GΩ, typical at 25 °C
    Maximum switching current 2 A (per channel)
    Maximum carry current 2 A (per channel)
    Minimum switch load 20 mV/1 mA
    Note The PXIe-2526 is not recommended for 2-wire resistance measurements.
    Notice Switching inductive loads (for example, motors and solenoids) can produce high-voltage transients in excess of the module’s rated voltage. Without additional protection, these transients can interfere with module operation and impact relay life. For more information about transient suppression, visit ni.com/info and enter the info code relayflyback.
    DC path resistance, initial <0.5 Ω, warranted
    DC path resistance, end-of-life ≥1.5 Ω

    DC path resistance is a combination of relay contact resistance and trace resistance. Measure path resistance by combining the resistance of the high and low signal paths from one row to one column. Contact resistance typically remains low for the life of a relay. At the end of relay life, the contact resistance rises rapidly at ≥1.5 Ω.

    Thermal EMF <10 µV

    RF Performance Characteristics

    Conditions for RF Performance Characteristics: Typical at 23 ºC) 50 Ω termination.

    Bandwidth (-3 dB, typical at 23 ºC) 50 Ω termination ≤10 MHz
    Table 1. Open Channel Isolation
    Frequency Isolation
    10 kHz ≥67 dB
    100 kHz ≥49 dB
    1 MHz ≥29 dB

    Dynamic Characteristics

    Relay operate time
    • 1 ms, typical
    • 3.1 ms, maximum
    • Simultaneous drive limit: 82 relays
    Expected relay life
    • Mechanical: 1 × 108 cycles
    • Electrical:
      • ≤30 mV, ≤10 mA resistive: 2.5 × 106 cycles
      • 30 V, 1 A: 5 × 105 cycles
      • 30 V, 2 A: 1 × 105 cycles
      • 60 V DC, 1 A DC resistive: 1 × 105 cycles
    Tip Relays are field replaceable. Refer to the documentation for your module on ni.com for more information about replacing a failed relay.

    Physical Characteristics

    Relay type Electromechanical, non-latching
    Relay contact material Palladium-ruthenium, gold covered
    Front panel connector 160 DIN 41612, 160 positions, male
    PXI Express power requirement
    • 12 V: 21 W
    • 3.3 V: 3.4 W
    Dimensions (L × W × H)
    • 3U, one slot, PXI/cPCI module, PXI Express compatible
    • 21.6 cm × 2.0 cm × 13.0 cm (8.5 in. × 0.8 in. × 5.1 in.)
    Weight 230 g (8.1 oz)

    Environment

    Maximum altitude 2,000 m (800 mbar) (at 25 °C ambient temperature)
    Pollution Degree 2

    Indoor use only.

    Operating Environment

    Ambient temperature range, operating 0 °C to 55 °C
    Relative humidity range, operating 10% to 90%, noncondensing

    Storage Environment

    Ambient temperature, storage -40 °C to 71 °C
    Relative humidity range, storage 5% to 95%, noncondensing

    Shock and Vibration

    Operating shock 30 g peak, half-sine, 11 ms pulse
    Random vibration
    • Operating: 5 Hz to 500 Hz, 0.3 g RMS
    • Nonoperating: 5 Hz to 500 Hz, 2.4 g RMS

    NI Accessories for the PXIe-2526

    Accessory NI Part Number
    DIN160 to 50-pin D-SUB switch cable, 1 m 782417-03
    DIN160 to DIN160 switch cable, 1 m 782417-02
    DIN160 to bare wire switch cable, 1 m 782417-01
    Relay replacement kit for IME02TS Relays 782461-10

    Compliance and Certifications

    Safety Compliance Standards

    This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:

    • IEC 61010-1, EN 61010-1
    • UL 61010-1, CSA C22.2 No. 61010-1
    Note For safety certifications, refer to the product label or the Product Certifications and Declarations section.

    Electromagnetic Compatibility

    This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
    • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
    • EN 55011 (CISPR 11): Group 1, Class A emissions
    • EN 55022 (CISPR 22): Class A emissions
    • EN 55024 (CISPR 24): Immunity
    • AS/NZS CISPR 11: Group 1, Class A emissions
    • AS/NZS CISPR 22: Class A emissions
    • FCC 47 CFR Part 15B: Class A emissions
    • ICES-001: Class A emissions
    Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations.
    Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes.
    Note For EMC declarations, certifications, and additional information, refer to Product Certifications and Declarations.

    Product Certifications and Declarations

    Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.

    Environmental Management

    NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.

    For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.

    EU and UK Customers

  • Waste Electrical and Electronic Equipment (WEEE)—At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.
  • 电子信息产品污染控制管理办法(中国RoHS)

  • 中国RoHSNI符合中国电子信息产品中限制使用某些有害物质指令(RoHS)。关于NI中国RoHS合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)