PXIe-2512 Overview
- Updated2023-02-19
- 2 minute(s) read
PXIe-2512 Overview
PXIe-2512 Pinout
| Signal | Description |
|---|---|
| BUSn | Fault bus connection |
| CHn | Signal connection |
| DUTn | DUT connection |
| LED | Color/State | Status |
|---|---|---|
| STATUS | Green | OK, no channel errors present on module |
| Red | Error detected on one or more channels on module | |
| DUTn | Off | Open channel |
| Green | Pass-through channel closed (CHn to DUTn) | |
| Blink Amber Once | DUTn connected to fault bus A | |
| Blink Amber Twice | DUTn connected to fault bus B | |
| Solid Amber | Any combination of multiple DUTn paths closed (CHn, BusA, BusB) | |
| Blink Red Once[1] | Overtemperature error detected on DUTn | |
| Solid Red[2] | Overcurrent error detected on DUTn |
PXIe-2512 Topology
This figure describes the topology of the module.
Module software name: 2512/Independent (NISWITCH_TOPOLOGY_2512_INDEPENDENT)
Independent Topology
Relays
- k0...k6
- k0a...k6a
- k0b...k6b
Making a Connection
Both the scanning command, dut1->busA;, and the immediate operation, niSwitch Connect Channels VI or the niSwitch_Connect function with parameters dut1 and busA, result in the following connection: