PXI-2521 Specifications
- Updated2025-05-22
- 6 minute(s) read
PXI-2521 Specifications
PXI-2521 Specifications
These specifications apply to the PXI-2521 .
All specifications are subject to change without notice.
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
Specifications are valid at 23 °C unless otherwise noted.
All voltages are specified in DC, ACpk, or a combination unless otherwise specified.
PXI-2521 Pinout
| Signal | Description |
|---|---|
| CHx+ | Positive signal connection |
| CHx- | Negative signal connection |
| COMx+ | Routing destination for the corresponding positive signal connection |
| COMx- | Routing destination for the corresponding negative signal connection |
Cleaning the Module
Clean devices and terminal blocks by brushing off light dust with a soft, nonmetallic brush. Remove other contaminants with a soft, lint-free, dampened cloth. Do not use detergent or chemical solvents. The unit must be completely dry and free from contaminants before returning to service.
Cautions
Input Characteristics
| |||||||
Maximum switching power (per channel) | 60 W, 62.5 VA (DC to 60 Hz) | ||||||
Maximum current (switching or carry, per channel) | 2 A | ||||||
Simultaneous channels at maximum current (≤55 °C) | 40 | ||||||
Minimum switching conditions | 20 mV/1 mA | ||||||
| |||||||
DC path resistance typically remains low for the life of the relay. At the end of relay life, the path resistance rises rapidly above 1 Ω. Load ratings apply to relays used within the specification before the end of relay life.
Thermal EMF (typical at 23 °C) | 12 µV | ||||||
| |||||||
| |||||||
| |||||||
Dynamic Characteristics
Relay operate time | 1 ms, typical 3.4 ms, maximum | ||||||||||||
Simultaneous drive limit | 40 relays | ||||||||||||
| |||||||||||||
Trigger Characteristics
| Sources | PXI trigger lines <0...7> |
| Minimum pulse width | 150 ns |
| Destinations | PXI trigger lines <0...7> |
| Default pulse width | 2 µs, typical |
Physical Characteristics
Relay type | Electromechanical, non-latching |
Relay contact material | Palladium-ruthenium, gold covered |
I/O connector | 160 DIN 41612, 160 positions, male |
Power requirement | 7 W at 5 V, 2.5 W at 3.3 V |
Dimensions (L × W × H) | 3U, one slot, PXI/cPCI module 21.6 cm × 2.0 cm × 13.0 cm (8.5 in. × 0.8 in. × 5.1 in.) |
Weight | 182 g (6.4 oz) |
Environment
| Maximum altitude | 2,000 m (at 25 °C ambient temperature) |
| Pollution degree | 2 |
| Indoor use only | |
Operating Environment
Ambient temperature range | 0 °C to 55 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.) |
Relative humidity range | 10% to 90%, noncondensing (Tested in accordance with IEC 60068-2-56.) |
Storage Environment
Ambient temperature range | -40 °C to 71 °C (Tested in accordance with IEC 60068-2-1 and IEC 60068-2-2.) |
Relative humidity range | 5% to 95%, noncondensing (Tested in accordance with IEC 60068-2-56.) |
Shock and Vibration
Operational shock | 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) | ||||||
| |||||||
Compliance and Certifications
Safety Compliance Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA C22.2 No. 61010-1
Electromagnetic Compatibility
- EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- EN 55022 (CISPR 22): Class A emissions
- EN 55024 (CISPR 24): Immunity
- AS/NZS CISPR 11: Group 1, Class A emissions
- AS/NZS CISPR 22: Class A emissions
- FCC 47 CFR Part 15B: Class A emissions
- ICES-001: Class A emissions
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.