PCI/PXI-6220 Specifications
- Updated2025-11-05
- 11 minute(s) read
PCI/PXI-6220 Specifications
PCI/PXI-6220 Specifications
These specifications apply to the PCI/PXI-6220.
The following specifications are typical at 25 °C, unless otherwise noted.
Revision History
| Version | Date changed | Description |
|---|---|---|
| 375200E-01 | August 2025 | Updated I/O connector specifications. |
| 375200D-01 | June 2025 | Added pinout diagrams. |
| 375200C-01 | June 2016 | Updated environmental and legal information. |
| 375200B-01 | September 2015 | Updated formatting. |
| 375200A-01 | July 2015 | Initial release. |
| 371290F-01 | June 2007 | Original specifications document: NI 622x Specifications. |
Looking For Something Else?
For information not found in the specifications for your product, such as operating instructions, browse Related Information.
PCI/PXI-6220 Pinout
Analog Input
| Number of channels | 8 differential or 16 single ended |
| ADC resolution | 16 bits |
| DNL | No missing codes guaranteed |
| INL | Refer to AI Absolute Accuracy |
| Timing accuracy | 50 ppm of sample rate |
| Timing resolution | 50 ns |
| Input coupling | DC |
| Input range | ±0.2 V, ±1 V, ±5 V, ±10 V |
| Maximum working voltage for analog inputs (signal + common mode) | ±11 V of AI GND |
| CMRR (DC to 60 Hz) | 92 dB |
| Input bias current | ±100 pA |
| Small signal bandwidth (-3 dB) | 700 kHz |
| Input FIFO size | 4,095 samples |
| Scan list memory | 4,095 entries |
| Data transfers | DMA (scatter-gather), interrupts, programmed I/O |
| Single channel maximum | 250 kS/s |
| Multichannel maximum (aggregate) | 250 kS/s |
| Minimum | No minimum |
| Device on, AI+ to AI GND | >10 GΩ in parallel with 100 pF |
| Device on, AI- to AI GND | >10 GΩ in parallel with 100 pF |
| Device off, AI+ to AI GND | 820 Ω |
| Device off, AI- to AI GND | 820 Ω |
| Adjacent channels | -75 dB |
| Non-adjacent channels | -90 dB |
| Device on | ±25 V for up to two AI pins |
| Device off | ±15 V for up to two AI pins |
| Input current during overvoltage condition | ±20 mA maximum/AI pin |
Settling Time for Multichannel Measurements
| ±90 ppm of step (±6 LSB) | 4 μs convert interval |
| ±30 ppm of step (±2 LSB) | 5 μs convert interval |
| ±15 ppm of step (±1 LSB) | 7 μs convert interval |
Typical Performance Graphs
AI Absolute Accuracy
| Nominal Range Positive Full Scale | Nominal Range Negative Full Scale | Residual Gain Error (ppm of Reading) | Residual Offset Error (ppm of Range) | Offset Tempco (ppm of Range/°C) | Random Noise, σ (μVrms) | Absolute Accuracy at Full Scale (μV) | Sensitivity (μV) |
|---|---|---|---|---|---|---|---|
| 10 | -10 | 75 | 20 | 57 | 244 | 3,100 | 97.6 |
| 5 | -5 | 85 | 20 | 60 | 122 | 1,620 | 48.8 |
| 1 | -1 | 95 | 25 | 79 | 30 | 360 | 12.0 |
| 0.2 | -0.2 | 135 | 80 | 175 | 13 | 112 | 5.2 |
| Gain tempco | 25 ppm/°C |
| Reference tempco | 5 ppm/°C |
| INL error | 76 ppm of range |
AI Absolute Accuracy Equation
AbsoluteAccuracy = Reading · (GainError) + Range · (OffsetError) + NoiseUncertainty
- GainError = ResidualAIGainError + GainTempco · (TempChangeFromLastInternalCal) + ReferenceTempco · (TempChangeFromLastExternalCal)
- OffsetError = ResidualAIOffsetError + OffsetTempco · (TempChangeFromLastInternalCal) + INLError
- NoiseUncertainty = for a coverage factor of 3 σ and averaging 100 points.
AI Absolute Accuracy Example
Absolute accuracy at full scale on the analog input channels is determined using the following assumptions:
- TempChangeFromLastExternalCal = 10 °C
- TempChangeFromLastInternalCal = 1 °C
- number_of_readings = 100
- CoverageFactor = 3 σ
For example, on the 10 V range, the absolute accuracy at full scale is as follows:
- GainError = 75 ppm + 25 ppm · 1 + 5 ppm · 10 = 150 ppm
- OffsetError = 20 ppm + 57 ppm · 1 + 76 ppm = 153 ppm
- NoiseUncertainty = = 73 µV
- AbsoluteAccuracy = 10 V · (GainError) + 10 V · (OffsetError) + NoiseUncertainty = 3,100 µV
Digital I/O and PFI
Static Characteristics
| Number of channels | 24 total, 8 (P0.<0..7>), 16 (PFI <0..7>/P1, PFI <8..15>/P2) |
| Ground reference | D GND |
| Direction control | Each terminal individually programmable as input or output |
| Pull-down resistor | 50 kΩ typical, 20 kΩ minimum |
| Input voltage protection | ±20 V on up to two pins[1]1 Stresses beyond those listed under Input voltage protection may cause permanent damage to the device. |
Waveform Characteristics (Port 0 Only)
| Terminals used | Port 0 (P0.<0..7>) |
| Port/sample size | Up to 8 bits |
| Waveform generation (DO) FIFO | 2,047 samples |
| Waveform acquisition (DI) FIFO | 2,047 samples |
| DI or DO Sample Clock frequency | 0 MHz to 1 MHz, system and bus activity dependent |
| Data transfers | DMA (scatter-gather), interrupts, programmed I/O |
| DI or DO Sample Clock source[2]2 The digital subsystem does not have its own dedicated internal timing engine. Therefore, a sample clock must be provided from another subsystem on the device or an external source. | Any PFI, RTSI, AI Sample or AI Convert Clock, Ctr n Internal Output, and many other signals |
PFI/Port 1/Port 2 Functionality
| Functionality | Static digital input, static digital output, timing input, timing output |
| Timing output sources | Many AI, counter, DI, DO timing signals |
| Debounce filter settings | 125 ns, 6.425 µs, 2.56 ms, disable; high and low transitions; selectable per input |
Recommended Operating Conditions
| Level | Minimum | Maximum |
|---|---|---|
| Input high voltage (VIH) | 2.2 V | 5.25 V |
| Input low voltage (VIL) | 0 V | 0.8 V |
| Output high current (IOH) P0.<0..7> | — | -24 mA |
| Output high current (IOH) PFI <0..15>/P1/P2 | — | -16 mA |
| Output low current (IOL) P0.<0..7> | — | 24 mA |
| Output low current (IOL) PFI <0..15>/P1/P2 | — | 16 mA |
Electrical Characteristics
| Level | Minimum | Maximum |
|---|---|---|
| Positive-going threshold (VT+) | — | 2.2 V |
| Negative-going threshold (VT-) | 0.8 V | — |
| Delta VT hysteresis (VT+ - VT-) | 0.2 V | — |
| IIL input low current (Vin = 0 V) | — | -10 µA |
| IIH input high current (Vin = 5 V) | — | 250 µA |
Digital I/O Characteristics
General-Purpose Counters/Timers
| Number of counter/timers | 2 |
| Resolution | 32 bits |
| Counter measurements | Edge counting, pulse, semi-period, period, two-edge separation |
| Position measurements | X1, X2, X4 quadrature encoding with Channel Z reloading; two-pulse encoding |
| Output applications | Pulse, pulse train with dynamic updates, frequency division, equivalent time sampling |
| Internal base clocks | 80 MHz, 20 MHz, 0.1 MHz |
| External base clock frequency | 0 MHz to 20 MHz |
| Base clock accuracy | 50 ppm |
| Inputs | Gate, Source, HW_Arm, Aux, A, B, Z, Up_Down |
| Routing options for inputs | Any PFI, RTSI, PXI_TRIG, PXI_STAR, analog trigger, many internal signals |
| FIFO | 2 samples |
| Data transfers | Dedicated scatter-gather DMA controller for each counter/timer; interrupts; programmed I/O |
Frequency Generator
| Number of channels | 1 |
| Base clocks | 10 MHz, 100 kHz |
| Divisors | 1 to 16 |
| Base clock accuracy | 50 ppm |
Output can be available on any output PFI or RTSI terminal.
Phase-Locked Loop (PLL)
| Number of PLLs | 1 |
| Reference signal | PXI_STAR, PXI_CLK10, RTSI <0..7> |
| Output of PLL | 80 MHz Timebase; other signals derived from 80 MHz Timebase including 20 MHz and 100 kHz Timebases |
External Digital Triggers
| Source | Any PFI, RTSI, PXI_TRIG, PXI_STAR |
| Polarity | Software-selectable for most signals |
| Analog input function | Start Trigger, Reference Trigger, Pause Trigger, Sample Clock, Convert Clock, Sample Clock Timebase |
| Counter/timer function | Gate, Source, HW_Arm, Aux, A, B, Z, Up_Down |
| Digital waveform generation (DO) function | Sample Clock |
| Digital waveform acquisition (DI) function | Sample Clock |
Device-to-Device Trigger Bus
| PCI | RTSI <0..7>[3]3 In other sections of this document, RTSI refers to RTSI <0..7> for the PCI devices or PXI_TRIG <0..7> for PXI devices. |
| PXI | PXI_TRIG <0..7>, PXI_STAR |
| Output selections | 10 MHz Clock, frequency generator output, many internal signals |
| Debounce filter settings | 125 ns, 6.425 μs, 2.56 ms, disable; high and low transitions; selectable per input |
Bus Interface
| PCI/PXI | 3.3 V or 5 V signal environment |
| DMA channels | 6, can be used for analog input, analog output, digital input, digital output, counter/timer 0, counter/timer 1 |
- May be installed in PXI Express hybrid slots
- Or, may be used to control SCXI in PXI/SCXI combo chassis
| M Series Part Number | SCXI Control in PXI/SCXI Combo Chassis | PXI Express Hybrid Slot Compatible |
|---|---|---|
| 191332B-04 | No | Yes |
| 191322A-0x | Yes | No |
Power Requirements
| +5 V | 0.02 A |
| +3.3 V | 0.25 A |
| +12 V | 0.15 A |
| +5 V | 0.02 A |
| +3.3 V | 0.25 A |
| +12 V | 0.25 A |
Current Limits
| +5 V terminal | 1 A maximum. See note. |
| +5 V terminal | 1 A maximum. See note. |
| P0/PFI/P1/P2 and +5 V terminals combined | 2 A maximum |
Physical Characteristics
| PCI printed circuit board | 10.6 cm ×
15.5 cm
(4.2 in. × 6.1 in.)
For more information, visit ni.com/dimensions and search by module number. |
| PXI printed circuit board | Standard 3U PXI For more information, visit ni.com/dimensions and search by module number. |
| PCI | 91 g (3.2 oz) |
| PXI | 158 g (5.5 oz) |
| Connector type | 1 68-pin VHDCI |
Calibration
You can obtain the calibration certificate and information about calibration services for the PCI/PXI-6220 at ni.com/calibration.
| Recommended warm-up time | 15 minutes |
| Calibration interval | 1 year |
Maximum Working Voltage
Connect only voltages that are below these limits.
| Channel-to-earth | 11 V, Measurement Category I |
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Environmental
| Characteristic | Specification |
|---|---|
| Operating | 0 ºC to 55 ºC |
| Storage | -20 ºC to 70 ºC |
| Humidity | 10% RH to 90% RH, noncondensing |
| Characteristic | Specification |
|---|---|
| Pollution Degree | 2 |
| Characteristic | Specification |
|---|---|
| Maximum altitude | 2,000 m |
| Characteristic | Specification |
|---|---|
| Operating vibration | 5 Hz to 500 Hz, 0.3 g RMS |
| Non-operating vibration | 5 Hz to 500 Hz, 2.4 g RMS |
| Operating shock | 30 g, half-sine, 11 ms pulse |
Indoor use only.
Safety Compliance Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
- IEC 61010-1, EN 61010-1
- UL 61010-1, CSA C22.2 No. 61010-1
EMC Standards
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
- EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
- EN 55011 (CISPR 11): Group 1, Class A emissions
- EN 55022 (CISPR 22): Class A emissions
- EN 55024 (CISPR 24): Immunity
- AS/NZS CISPR 11: Group 1, Class A emissions
- AS/NZS CISPR 22: Class A emissions
- FCC 47 CFR Part 15B: Class A emissions
- ICES-001: Class A emissions
CE Compliance
This product meets the essential requirements of applicable European Directives, as follows:
- 2014/35/EU; Low-Voltage Directive (safety)
- 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
- 2011/65/EU; Restriction of Hazardous Substances (RoHS)
Product Certifications and Declarations
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Engineering a Healthy Planet web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.
EU and UK Customers
电子信息产品污染控制管理办法(中国RoHS)
1 Stresses beyond those listed under Input voltage protection may cause permanent damage to the device.
2 The digital subsystem does not have its own dedicated internal timing engine. Therefore, a sample clock must be provided from another subsystem on the device or an external source.
3 In other sections of this document, RTSI refers to RTSI <0..7> for the PCI devices or PXI_TRIG <0..7> for PXI devices.