Returns the I/Q data as a complex waveform data type (WDT).

Supported Devices: PXIe-5644/5645/5646, PXI-5661, PXIe-5663/5663E/5665/5667/5668, PXIe-5820/5830/5831/5832/5840/5841/5842/5860


icon

Inputs/Outputs

  • cu16.png timestamp type

    timestamp type specifies the time format of the data output. The default value is Relative.

    Relative The timestamp corresponds to the difference, in seconds, between the first sample returned and the Reference Trigger location. The timestamp is zero if the Reference Trigger has not occurred.
    Absolute The timestamp corresponds to the date and time of the acquisition of the first sample returned.
    Note The value of the absolute timestamp returned is always 0 for the PXIe-5644/5645/5646, PXIe-5668, and PXIe-5820/5830/5831/5832/5840/5841/5842/5860. The value of the relative timestamp returned is always 0 for the PXIe-5644/5645/5646 and PXIe-5820/5830/5831/5832/5840/5841/5842/5860.
  • civrn.png instrument handle

    instrument handle identifies your instrument session. instrument handle is obtained from the niRFSA Initialize VI or the niRFSA Initialize With Options VI.

  • cdbl.png timeout (10 sec)

    timeout specifies the time, in seconds, allotted for the VI to complete before returning a timeout error. A value of -1 specifies that the VI waits until all data is available. The default value is 10 seconds.

  • cerrcodeclst.png error in

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • iivrn.png instrument handle out

    instrument handle out passes a reference to your instrument session to the next VI. instrument handle is obtained from the niRFSA Initialize VI or the niRFSA Initialize With Options VI and identifies a particular instrument session.

  • imsdt.png data

    data returns the baseband (downconverted) time-domain data for demodulation.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.