Fetches I/Q data from a single record in an acquisition.

Supported Devices: PXIe-5644/5645/5646, PXI-5661, PXIe-5663/5663E/5665/5667/5668, PXIe-5820/5830/5831/5832/5840/5841/5842/5860


icon

Inputs/Outputs

  • cu16.png timestamp type

    timestamp type specifies the time format of the data output. The default value is Relative.

    Relative The timestamp corresponds to the difference, in seconds, between the first sample returned and the Reference Trigger location. The timestamp is zero if the Reference Trigger has not occurred.
    Absolute The timestamp corresponds to the date and time of the acquisition of the first sample returned.
    Note The value of the absolute timestamp returned is always 0 for the PXIe-5644/5645/5646, PXIe-5668, and PXIe-5820/5830/5831/5832/5840/5841/5842/5860. The value of the relative timestamp returned is always 0 for the PXIe-5644/5645/5646 and PXIe-5820/5830/5831/5832/5840/5841/5842/5860.
  • ci64.png record to fetch

    record to fetch specifies the record to retrieve. Record numbers are zero-based. The default value is 0.

  • civrn.png instrument handle

    instrument handle identifies your instrument session. instrument handle is obtained from the niRFSA Initialize VI or the niRFSA Initialize With Options VI.

  • ci64.png samples to read (-1)

    samples to read specifies the number of samples to fetch. A value of -1 specifies that NI-RFSA fetches all samples. The default value is -1.

    Note Setting samples to read to –1 fetches all remaining samples currently available depending on the Fetch Relative To property and the Fetch Offset property settings.
  • cdbl.png timeout (10 sec)

    timeout specifies the time, in seconds, allotted for the VI to complete before returning a timeout error for the PXI-5661, PXIe-5663/5665/5667. Specifies the time, in seconds, allotted to receive the reference trigger for the PXIe-5644/5645/5646, PXIe-5668, and PXIe-5820/5830/5831/5832/5840/5841/5842/5860.

    Note A value of -1 specifies that the VI waits until all data is available. A value of 0 specifies the VI immediately returns available data. The default value is 10.
  • cerrcodeclst.png error in

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • iivrn.png instrument handle out

    instrument handle out passes a reference to your instrument session to the next VI. instrument handle is obtained from the niRFSA Initialize VI or the niRFSA Initialize With Options VI and identifies a particular instrument session.

  • imsdt.png data

    data returns the baseband (downconverted) time-domain data for demodulation.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.