niRFSA Fetch IQ (1D Complex WDT NRec 1Chan) VI
- Updated2025-10-14
- 4 minute(s) read
Fetches I/Q data from multiple records in an acquisition.
Supported Devices: PXIe-5644/5645/5646, PXI-5661, PXIe-5663/5663E/5665/5667/5668, PXIe-5820/5830/5831/5832/5840/5841/5842/5860

Inputs/Outputs
timestamp type
—
timestamp type specifies the time format of the data output. The default value is Relative.
Note The value of the absolute timestamp returned is always 0 for the PXIe-5644/5645/5646, PXIe-5668, and PXIe-5820/5830/5831/5832/5840/5841/5842/5860. The value of the relative timestamp returned is always 0 for the PXIe-5644/5645/5646 and PXIe-5820/5830/5831/5832/5840/5841/5842/5860.
number of records (-1)
—
number of records specifies the number of records to fetch. A value of -1 specifies that NI-RFSA fetches all records in an acquisition. Record numbers are zero-based. The default value is -1. If starting record is set to a value greater than 0, setting number of records to –1 returns an error. If you set starting record to a value greater than 0, set number of records to the exact number of records to fetch. Note If you set number of records to 0, this VI returns an error.
starting record
—
starting record specifies the first record to retrieve. Record numbers are zero-based. The default value is 0.
instrument handle
—
instrument handle identifies your instrument session. instrument handle is obtained from the niRFSA Initialize VI or the niRFSA Initialize With Options VI.
samples to read (-1)
—
samples to read specifies the number of samples to fetch. A value of -1 specifies that NI-RFSA fetches all samples. The default value is -1. Note Setting samples to read to –1 fetches all remaining samples currently available depending on the
Fetch Relative To property and the
Fetch Offset property settings.
timeout (10 sec)
—
timeout specifies the time, in seconds, allotted for the VI to complete before returning a timeout error for the PXI-5661, PXIe-5663/5665/5667. Specifies the time, in seconds, allotted to receive the reference trigger for the PXIe-5644/5645/5646, PXIe-5668, and PXIe-5820/5830/5831/5832/5840/5841/5842/5860. Note A value of -1 specifies that the VI waits until all data is available. A
value of 0 specifies the VI immediately returns available data. The default value is 10.
error in
—
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
instrument handle out
—
instrument handle out passes a reference to your instrument session to the next VI. instrument handle is obtained from the niRFSA Initialize VI or the niRFSA Initialize With Options VI and identifies a particular instrument session.
data
—
data returns the acquired waveform.
error out
—
error out contains error information. This output provides standard error out functionality. |
timestamp type
—
number of records (-1)
—
instrument handle
—
timeout (10 sec)
—
error in
—
instrument handle out
—
data
—