Creates an empty configuration list for RF list mode. After a configuration list is created, enable the list using the set as active list input. Call the niRFSA Create Configuration List Step VI to add steps to the active configuration list.

Supported Devices: PXIe-5644/5645/5646, PXIe-5663E/5665/5667, PXIe-5820/5830/5831/5832/5840/5841/5842/5860, PXIe-5842 with S-parameters, PXIe-5842 with 54GHz Frequency Extension

Related Topics

RF List Mode


icon

Inputs/Outputs

  • civrn.png instrument handle

    instrument handle identifies your instrument session. instrument handle is obtained from the niRFSA Initialize VI or the niRFSA Initialize With Options VI.

  • cstr.png list name

    list name specifies the name of the configuration list. This string may not contain spaces, special characters, or punctuation marks.

  • c1di32.png configuration list properties

    configuration list properties specifies the properties that you intend to change between configuration list steps. Calling the niRFSA Create Configuration List VI allocates space for each of the configuration list properties. When you use the NI-RFSA property node to set one of the configuration list properties, that property is set as one of the configuration list steps. Specify which configuration list step is being configured using the Active Configuration List property.

    You can include the following properties in your configuration list based on your device:

    Property PXIe-5663E PXIe-5665 PXIe-5667 PXIe-5644/5646 PXIe-5645 PXIe-5820 PXIe-5830/5831/5832 PXIe-5840/5841 PXIe-5841 with PXIe-5655 PXIe-5842, PXIe-5842 with S-parameters, PXIe-5842 with 54GHz Frequency Extension PXIe-5860
    Channel Coupling
    Device Instantaneous Bandwidth
    Downconverter Center Frequency
    Downconverter Frequency Offset
    Downconverter Frequency Offset Mode
    Downconverter Preselector Enabled ✓ (PXIe-5665 (14 GHz) only) ✓ (PXIe-5667 (7 GHz) only)
    External Gain
    Frequency Settling
    IF Filter Bandwidth
    IF Output Power Level
    IF Output Power Level Offset
    IQ Carrier Frequency
    IQ In Port Carrier Frequency
    IQ In Port Vertical Range
    IQ Power Edge Trigger Level
    LO Source
    Low Frequency Bypass Enabled
    Mechanical Attenuation
    Mechanical Attenuator Enabled
    Minimum ACPR
    Notch Filter Enabled
    Number of Samples
    OSP Data Scaling Factor
    Reference Level
    RF Attenuation
    RF Out LO Export Enabled
    RF Preamp Enabled
    RF Preselector Filter
    Timer Event Interval
  • cbool.png set as active list

    set as active list sets this list as the active configuration list when this parameter is set to TRUE. The default value is TRUE.

  • cerrcodeclst.png error in

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • iivrn.png instrument handle out

    instrument handle out passes a reference to your instrument session to the next VI. instrument handle is obtained from the niRFSA Initialize VI or the niRFSA Initialize With Options VI and identifies a particular instrument session.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.