Configures the device to wait for a digital edge Reference Trigger to mark a reference point within the record.

You can use this trigger with the NI-TClk API.

Note The PXIe-5644/5645/5646 does not support the NI-TClk API.

Supported Devices: PXIe-5644/5645/5646, PXI-5661, PXIe-5663/5663E/5665/5667/5668, PXIe-5820/5830/5831/5832/5840/5841/5842/5860


icon

Inputs/Outputs

  • ci64.png pretrigger samples

    pretrigger samples specifies the number of samples to store for each record that was acquired in the time period immediately before the trigger occurred. The default value is 0.

  • civrn.png instrument handle

    instrument handle identifies your instrument session. instrument handle is obtained from the niRFSA Initialize VI or the niRFSA Initialize With Options VI.

  • cstr.png source

    source specifies the source of the digital edge for the Reference Trigger.

    PFI0 The trigger is received on PFI 0. For the PXIe-5841 with PXIe-5655, the trigger is received on the PXIe-5841 PFI 0.
    PFI1 The trigger is received on PFI 1.
    PXI_Trig0 The trigger is received on PXI trigger line 0.
    PXI_Trig1 The trigger is received on PXI trigger line 1.
    PXI_Trig2 The trigger is received on PXI trigger line 2.
    PXI_Trig3 The trigger is received on PXI trigger line 3.
    PXI_Trig4 The trigger is received on PXI trigger line 4.
    PXI_Trig5 The trigger is received on PXI trigger line 5.
    PXI_Trig6 The trigger is received on PXI trigger line 6.
    PXI_Trig7 The trigger is received on PXI trigger line 7.
    PXI_STAR The trigger is received on the PXI star trigger line. This value is not supported by the PXIe-5644/5645/5646.
    PXIe_DStarB The trigger is received on the PXIe DStar B trigger line. This value is valid on only the PXIe-5820/5830/5831/5832/5840/5841/5842/5860.
    TimerEvent The trigger is received from Timer Event on the digitizer. This value is valid on only the PXIe-5820/5830/5831/5832/5840/5841/5842/5860 and for digital edge Advance Triggers on the PXIe-5644/5645/5646 and PXIe-5663E/5665.
    PulseIn The trigger is received from PULSE IN terminal. This value is valid on only the PXIe-5842.
  • ci32.png edge

    edge specifies the trigger edge to detect. The default value is Rising Edge.

    Rising Edge NI-RFSA detects a rising edge.
    Falling Edge NI-RFSA detects a falling edge.
  • cerrcodeclst.png error in

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • iivrn.png instrument handle out

    instrument handle out passes a reference to your instrument session to the next VI. instrument handle is obtained from the niRFSA Initialize VI or the niRFSA Initialize With Options VI and identifies a particular instrument session.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.