Erase Firmware (VI)
- Updated2023-02-21
- 3 minute(s) read
Removes the firmware image from the resource or target.

![]() |
Stop Tasks Automatically specifies to automatically end all tasks running on the target, even if they are incomplete and switch to firmware update mode. The default is TRUE. |
![]() |
Resource in is the resource from which you want to erase the firmware image. |
![]() |
error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality. |
![]() |
Remote Timeout specifies the time in milliseconds that this VI waits to initiate the firmware process before it times out. The default amount of time that the VI waits for a response on the network before timing out is 5 minutes. This timeout is for remote systems only. |
![]() |
Resource out returns basic information about the system resource. |
![]() |
Detailed Result returns a string containing results of any errors that may have occurred during the VI execution. This parameter also may return additional information about the value returned in Firmware Status . |
![]() |
Firmware Status returns the status of the firmware update. If this parameter returns update pending user restart , call the Restart VI. If this parameter returns update pending user action , refer to Detailed Result for more information. |
![]() |
error out returns error information. This output provides standard error out functionality. |
![]() |
Previous Firmware Version is the firmware version you removed from the resource. |