niSwitch Route Scan Advanced Output VI
- Updated2025-04-18
- 3 minute(s) read
Routes the scan advanced output trigger from a trigger bus line (TTLx) to the front or rear connector.
Use this VI when handshaking with a switch module that is not directly cabled to the controller. In this module's session, set the scan advanced output bus line to a trigger bus line. In the cabled module's session, use this VI to route from the trigger bus line to the front or rear connector of the cabled module.
If this VI is used to route scan advanced from a TTL line, specify the TTL line as the scan advanced output destination in the niSwitch Configure Scan Trigger VI.
Related Topics

Inputs/Outputs
![]() invert inverts the input trigger signal from rising to falling and falling to rising. The default value is FALSE (0).
![]() instrument handle identifies a particular NI-SWITCH session established with the niSwitch Initialize With Topology VI, the niSwitch Initialize With Options VI, or the niSwitch Initialize VI. ![]() scan advanced output connector is the Scan Advanced Output destination. Valid locations are the front and rear connectors. ![]() scan advanced output bus line is the trigger line to route the scan advanced output trigger from the front or rear connector. Select None (default) to break an existing route. ![]() error in describes error conditions that occur before this node runs. This input provides standard error in functionality. ![]() instrument handle out identifies a particular NI-SWITCH session established with the niSwitch Initialize With Topology VI, the niSwitch Initialize With Options VI, or the niSwitch Initialize VI and used for all subsequent NI-SWITCH calls. ![]() error out contains error information. This output provides standard error out functionality. |