Configure RFmx Attenuation (XML File) VI
- Updated2024-12-03
- 3 minute(s) read
Specifies the absolute path to the RF system calibration XML file created using the RF System Calibration Assistant. Use the RF System Calibration Assistant to save multiple analyzer path calibrations in a single xml file. Specify the path to use with the RFmx Attenuation Path Name input. Although the RF System Calibration Assistant allows you to calibrate one path at multiple reference levels for the same frequency, this API supports calibrations done at only one reference level for each frequency. This function returns an error if you do not wire the RFmx XML File Path input or specify an empty or relative path.

Inputs/Outputs
PAE Reference In
—
Specifies the session reference handle of the PAE measurement session.
RFmx Attenuation Enabled
—
Specifies whether RFmx is configured to compensate for external attenuation. The default value is False.
RFmx XML File Path
—
Specifies the absolute path to the XML file generated by the RF System Calibration Utility. The default value is empty.
RFmx Attenuation Path Name
—
Specifies the name of the analyzer path to use. This path is specified by the XML file created with the RF System Calibration Assistant.
error in
—
Error conditions that occur before this node runs. This input provides standard error in functionality.
PAE Reference Out
—
Returns the session reference handle of the PAE measurement session.
error out
—
Error information. This output provides standard error out functionality. |
PAE Reference In
—
RFmx Attenuation Enabled
—
RFmx XML File Path
—
RFmx Attenuation Path Name
—
error in
—
PAE Reference Out
—
error out
—