Configure Digital Level Pause Trigger

Configures the Pause trigger as a level trigger.

Inputs/Outputs

datatype_icon

session in

Instrument session obtained from the Initialize Acquisition Sessionnode, the Initialize Generation Sessionnode, or the Initialize External Calibrationnode.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Default value: No error

datatype_icon

source

The specified trigger source.

You can choose PFI <0..3>, PFI <24..31>, PXI Trigger Line/RTSI <0..7>, PXI STAR Line, or PXIe DStarB.

Note Only the PXIe-6555/6556 devices support PFI <24..31> and PXIe DStarB.
datatype_icon

trigger when

The active level for the desired trigger.

High Level Trigger is active while the signal specified by the source is high.
Low Level Trigger is active while the signal specified by the source is low.

Default value: High Level

datatype_icon

session out

Handle that identifies the session in all subsequent node calls.

The session out parameter is obtained from the Initialize Acquisition Sessionnode or the Initialize Generation Sessionnode.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior