Closes an NI-FGEN external calibration session to PXIe-5413/5423/5433 waveform generators. If specified, this VI stores the new calibration constants and calibration data, such as time and temperature, in the onboard memory.


icon

Inputs/Outputs

  • cni5433_Ext_Cal_APIlvclass.png external cal session

    External Cal Session identifies an external calibration session.

  • cenum.png action

    Action specifies the action to perform upon closing.

    Input Description
    Abort Disregards the new calibration constants before closing
    Commit Stores the new calibration constants on the device before closing
  • cerrcodeclst.png error in

    error in describes error conditions that occur before this node runs.

    The default is no error. This node executes regardless of an incoming error.

    This input contains status, code, and source, which provide standard error in functionality.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.