NI-9263 Specifications
- Updated2025-08-11
- 6 minute(s) read
NI-9263 Specifications
These specifications apply to the NI-9263.
Revision History
| Version | Date changed | Description |
|---|---|---|
| 378838B-01 | August 2025 | Added the product pinout and clarified the weight of the spring terminal variant. |
| 378838A-01 | June 2022 | Initial release. |
Looking For Something Else?
For information not found in the specifications for your product, such as operating instructions, browse Related Information.
Connector Types
The NI-9263 has more than one connector type: NI-9263 with screw terminal and NI-9263 with spring terminal. Unless the connector type is specified, NI-9263 refers to both connector types.
Definitions
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
- Typical specifications describe the performance met by a majority of models.
- Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
Specifications are Typical unless otherwise noted.
Conditions
Specifications are valid under the following conditions unless otherwise noted.
- -40 °C to 70 °C
- All voltages are relative to COM
NI-9263 Pinout
| Signal Name | Description |
|---|---|
| AO | Analog output signal connection |
| COM | Common reference connection to isolated ground |
| NC | No connection |
Physical Characteristics
| Dimensions |
Visit ni.com/dimensions and search by module number. |
| Weight |
|
| Gauge | 0.2 mm2 to 2.5 mm2 (26 AWG to 14 AWG) copper conductor wire |
| Wire strip length | 13 mm (0.51 in.) of insulation stripped from the end |
| Temperature rating | 90 °C, minimum |
| Torque for screw terminals | 0.5 N · m to 0.6 N · m (4.4 lb · in. to 5.3 lb · in.) |
| Wires per screw terminal | One wire per screw terminal; two wires per screw terminal using a 2-wire ferrule |
| Ferrules | 0.25 mm2 to 2.5 mm2 |
| Gauge | 0.2 mm2 to 2.5 mm2 (26 AWG to 14 AWG) copper conductor wire |
| Wire strip length | 10 mm (0.39 in.) of insulation stripped from the end |
| Temperature rating | 90 °C, minimum |
| Torque for spring terminals | 0.5 N · m to 0.6 N · m (4.4 lb · in. to 5.3 lb · in.) |
| Wires per spring terminal | One wire per spring terminal; two wires per spring terminal using a 2-wire ferrule |
| Ferrules | 0.25 mm2 to 2.5 mm2 |
| Securement type | Screw flanges provided |
| Torque for screw flanges | 0.2 N · m (1.80 lb · in.) |
Environmental Guidelines
Environmental Characteristics
| Characteristic | Specification |
|---|---|
| Operating | -40 °C to 70 °C |
| Storage | -40 °C to 85 °C |
| Characteristic | Specification |
|---|---|
| Operating | 10% RH to 90 % RH, noncondensing |
| Storage | 5% RH to 95 % RH, noncondensing |
| Characteristic | Specification |
|---|---|
| Ingress protection | IP40 |
| Characteristic | Specification |
|---|---|
| Pollution degree | 2 |
| Characteristic | Specification |
|---|---|
| Maximum altitude |
|
| Operating vibration - Random | 5 g RMS, 10 Hz to 500 Hz |
| Operating vibration - Sinusoidal | 5 g, 10 Hz to 500 Hz |
| Operating shock | 30 g, 11 ms half sine; 50 g, 3 ms half sine; 18 shocks at 6 orientations |
To meet these shock and vibration specifications, you must panel mount the system.
Output Characteristics
| Number of channels | 4 analog output channels |
| DAC resolution | 16 bit |
| DAC type | String |
| Power-on output state | Channels off |
| Startup voltage[1]1 When the module powers on, a glitch occurs for 20 μs peaking at -1.5 V. | 0 V |
| Power-down voltage[2]2 The power-down voltage peaks at 1.8 V before exponentially discharging to 0 V in 100 μs. To reduce the peak voltage, add a 10 kΩ load. | 0 V |
| Current drive | ±1 mA per channel maximum |
| Output impedance | 2 Ω |
| Slew rate | 4 V/μs |
| Crosstalk | 76 dB |
| Capacitive drive | 1,500 pF minimum |
| Monotonicity | 16 bits |
| DNL | ±1 LSB maximum |
| INL (endpoint) | ±12 LSB maximum |
| MTBF | 1,732,619 hours at 25 °C; Bellcore Issue 2, Method 1, Case 3, Limited Part Stress Method |
| Nominal | ±10 V |
| Minimum | ±10.4 V |
| Typical | ±10.7 V |
| Maximum | ±11 V |
| Measurement Conditions | Temperature Range | Percent of Reading (Gain Error) | Percent of Range[3]3 Range equals ±10.7 V (Offset Error) |
|---|---|---|---|
| Calibrated | Maximum (-40 °C to 70 °C) | 0.35% | 0.75% |
| Calibrated | Typical (25 °C, ±5 °C) | 0.35% | 0.75% |
| Uncalibrated [4]4 Uncalibrated accuracy refers to the accuracy achieved when acquiring in raw or unscaled modes where the calibration constants stored in the module are not applied to the data. | Maximum (-40 °C to 70 °C) | 2.2% | 1.7% |
| Uncalibrated | Typical (25 °C, ±5 °C) | 0.3% | 0.25% |
| Gain drift | 11 ppm/°C |
| Offset drift | 110 μV/°C |
| Overvoltage | ±30 V |
| Short-circuit | Indefinitely |
| Number of Channels | Update Time for All Other Chassis | Update Time for cRIO-9151 R Series Expansion Chassis |
|---|---|---|
| 1 | 3 μs minimum | 3.5 μs minimum |
| 2 | 5 μs minimum | 6.5 μs minimum |
| 3 | 7.5 μs minimum | 9 μs minimum |
| 4 | 9.5 μs minimum | 12 μs minimum |
| Updating at 100 kS/s | 600 μV RMS |
| Not updating | 260 μV RMS |
| Full-scale step | 20 μs |
| 1 V step | 13 μs |
| 0.1 V step | 10 μs |
Power Requirements
| Active mode (at -40 °C) | 500 mW maximum |
| Sleep mode | 25 μW maximum |
| Active mode | 750 mW maximum |
| Sleep mode | 25 μW maximum |
Safety Voltages
Connect only voltages that are within the following limits:
| Channel-to-channel | None |
| Continuous | 250 V RMS, Measurement Category II |
| Withstand | 2,300 V RMS, verified by a 5 s dielectric withstand test |
Measurement Category II
Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe.
Calibration
| Recommended calibration interval | 1 year |
1 When the module powers on, a glitch occurs for 20 μs peaking at -1.5 V.
2 The power-down voltage peaks at 1.8 V before exponentially discharging to 0 V in 100 μs. To reduce the peak voltage, add a 10 kΩ load.
3 Range equals ±10.7 V
4 Uncalibrated accuracy refers to the accuracy achieved when acquiring in raw or unscaled modes where the calibration constants stored in the module are not applied to the data.