Chassis Grounding Screw
The NI-9154 provides a chassis grounding screw.
- Chassis Grounding Screw
For EMC compliance, you must connect the NI-9154 to earth ground through the chassis ground screw. Use wire that is 2.05 mm2 (12 AWG) solid copper wire with a maximum length of 1.5 m (5 ft). Attach the wire to the earth ground of the electrode system of the facility.
Caution If you use shielded cabling to connect to a C Series module with a plastic connector, you must attach the cable shield to the chassis grounding terminal using 1.3 mm diameter (16 AWG) or larger wire. Attach a ring lug to the wire and attach the wire to the chassis grounding terminal. Solder the other end of the wire to the cable shield. Use shorter wire for better EMC performance.