ETX-16400/16401 Specifications
- Updated2025-10-31
- 11 minute(s) read
ETX-16400/16401 Specifications
These specifications apply to the ETX-16400/16401.
Revision History
| Version | Date Changed | Description |
|---|---|---|
| 379243A-01 | October 2025 | Initial release. |
Looking For Something Else?
For information not found in the specifications for your product, such as operating instructions, browse Related Information.
Definitions
Warranted Specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Specifications account for measurement uncertainties, temperature drift, and aging. Specifications are ensured by design or verified during production and calibration.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
Values are Typical unless otherwise noted.
Conditions
Refer to ni.com/docs for detailed specifications on the specific instruments used within the ETX-16400/16401.
These specifications apply to all ETX-16400/16401 configuration options unless otherwise noted. Specifications are valid for the system and all included instruments under the following conditions unless otherwise noted.
- High-Power Production Test Base System environmental characteristics are met
- Instrument-level conditions are met
Calibration Conditions
The performance of an externally calibrated instrument is defined in the instrument specifications. Additionally, specifications for externally calibrated instruments are only valid if the conditions defined in the instrument specifications are met.
ETX-1640x Mass Interconnect Pinouts
The ETX-1640x has a mass interconnect component with the following measurement category, isolation voltages, and pinouts.
Measurement Category
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
Isolation Voltages
Isolation voltages only apply to hazardous voltage pins on the J13 and J15 mass interconnect connectors in the ETX-1640x.
Connectors not referenced in the following table have no isolation voltage ratings and are not intended to handle voltages above 30 V RMS, 60 V DC, or 42.4 V peak.
| Connector | Isolation Barrier | Maximum Working Voltage | Transient Overvoltage |
|---|---|---|---|
| J13 | Channel-to-ground/earth (Common Mode) | 300 V DC | 0 V peak |
| J15 | Channel-to-ground/earth (Common Mode) | 1500 V DC | 0 V peak |
J1 Pinout: Adapter Control and Communication
Refer to Additional Components for more information about the component type associated with J1.
J2 Pinout: DC PDU 1
J4 Pinout: DMM1, MATRIX1, and SMU1
Refer to Additional Components for more information about the component type associated with J4.
J6: RMX_PPS1
Refer to Additional Components for more information about the component type associated with J6.
J13: DMM2 and MUX1
Refer to Additional Components for more information about the component type associated with J13.
J15: Power Signals DAQ Voltage
Refer to Power Signals DAQ for more information about the component type associated with J15.
J17: CAN, LIN, and AO
Refer to Additional Components for more information about the component type associated with J17.
J18: Power Signals DAQ Current
Refer to Power Signals DAQ for more information about the component type associated with J18.
Input Voltage for the Power Entry Panel
The power entry panel (PEP) used in your system depends on your High-Power Production Test Base System model.
Input voltage range information is located in the ETX-1640x User Manual and ETX-1640x Specifications.
| Specification | RMX-10140-50D4P (ETX-16400) | RMX-10140-50Y2P (ETX-16401) |
|---|---|---|
| Overall power consumption | 40 kW | 30 kW |
| Overvoltage category | II | II |
| Branch circuit rating | 63 A | 63 A |
| Voltage rating | 480 V 3P+PE, 3Φ | 100 V/173 V to 240 V/415 V, 3P+N+PE, 3Φ |
| Frequency | 50 Hz or 60 Hz | 50 Hz or 60 Hz |
| Current rating | 50 A | 50 A |
Field Wiring Cable Specifications
The field wiring cable supplies power and protective earth for the ETX-1640x through internal terminal connections. Before performing initial power setup, you must provide a field wiring cable. The cable must meet the requirements in the following table.
| Outer diameter of the input power cable | 22.2 mm to 32 mm |
|---|---|
| Ground wiring | 2.5 mm2 to 70 mm2 (14 AWG to 2/0 AWG) |
| Wire strip length | 15.7 mm (0.6 in.) |
| Wiring for L1, L2, L3, and N[1]1 Neutral is applicable only for systems with the RMX-10140-50Y2P power entry panel. | 10 mm2 to 35 mm2 (8 AWG to 2 AWG) with M6 ring lugs installed |
| Minimum insulator temperature rating | 90 °C (194 °F) |
Receiver Ratings
Hazardous voltages may be applied to the modules in the following table.
| Module | Maximum Input Voltage (Maximum Voltage Sink) |
|---|---|
| J13 | 300 V DC |
| J15 | 1500 V DC |
ETX-1640x Physical Characteristics
Ensure the location, including passageways and elevators, can accommodate the size and weight of the ETX-1640x.
| Dimensions | 1157.79 mm × 679 mm × 1971 mm (45.58 in. × 26.7 in. × 77.6 in.) |
|---|---|
| Maximum weight as shipped |
ETX-16400: 344 kg (758 lb) ETX-16401: 336.6 kg (742 lb) |
| Acoustic emissions | 64 dB, 1 m away |
ETX-1640x Ventilation Clearances
Ventilation clearances are required to ensure proper airflow to the ETX-1640x. Ensure obstructions are outside the following clearance requirements.
| Left and right sides | 0 mm (0 in.) |
|---|---|
| ITA side | 0 mm (0 in.) |
| HMI side | 305 mm (12 in.) |
| Top | 508 mm (20 in.) |
ETX-1640x Hardware Components
The ETX-1640x is a rack-based system that comprises individual hardware components and instruments.
Component Locator Images
- Monitor
- PXI chassis
- RM-26999 (x2)
- RMX-41041
- VPC 9025
- 63 A branch breaker
- Facility power source entry point
- Input power terminal block (located in the protective enclosure)
- Fan panel DC power
- AC power distribution unit (PDU) 3
- 3-Phase AC PDU
- 63 A branch breaker for 3-phase AC PDU
- DC PDU 2 (AUX DC 1200)
- Power distribution terminal block
- Single-phase, 20 A branch breaker
- Rack control unit (RCU) DC power supply
- DC PDU 1 (AUX DC 600)
- AC PDU 1
- AC PDU 2 (AC PDU 2 is behind AC PDU 1 in the image)
- 480 V Transformer (ETX-16400 only)
Power Signals DAQ Components
Use the Power Signals DAQ to perform voltage and current measurements in the ETX-1640x.
| Component Type | Model, NI Part Number | Resource name | Ratings Override | PXI Chassis Slot | Mass Interconnect Slot |
|---|---|---|---|---|---|
| Multifunction I/O | PXIe-6368, 785926-01 |
PWRSIGDAQ1_SMIO1 | — | 17 | — |
| Power measurements conditioner | RM-26999 (Quantity: 2), 786328-01 |
PWRSIGDAQ1_PMC1 PWRSIGDAQ1_PMC2 |
1500 V DC, Category I Supported transducers: DS50UB-10V DS200UB-10V DS600UB-10V DM1200UB-10V DL2000UB-10V |
— | J15 and J18 |
Additional Components
The following components are independent of the composite instruments, and you can configure and use these components individually in the ETX-1640x. Additional components have an NI part number unless otherwise noted.
| Component type | Model, NI Part Number | Resource Name | Ratings Override | PXI Chassis Slot | Mass Interconnect Slot |
|---|---|---|---|---|---|
| PXI chassis | PXIe-1084, 784058-01 |
PXIChassis1 | — | — | — |
| PXI controller | PXIe-8862, Contact NI |
User-specified | — | 1 | — |
| Digital multimeter | PXIe-4082, 783131-01 |
DMM1 | ±60 V | 6 | J4 |
| Power supply | RMX-41041, 786014-01 |
RMX_PPS1 | — | — | J6 |
| Source measure unit | PXIe-4139, 782856-02 |
SMU1 | — | 7 | J4 |
| Multiplexer | PXIe-2527, 780587-27 |
MUX1 | — | 9 | J13 |
| Matrix | PXIe-2737, 782835-37 |
MATRIX1 | — | 5 | J4 |
| Bank-isolated digital I/O module | PXI-6528, 778543-01 |
DIO1 | 32 channels (16 source/sink inputs in 2 banks, 16 source/sink outputs in 2 banks) | 3 | J1 |
| Analog output | PXIe-4322, 782878-01 |
AO1 | — | 13 | J17 |
| RS232 serial instrument control module | PXIe-8430/8, 781472-01 |
COM2 COM3 |
2-port | 4 | J1 |
| CAN/LIN | PXIe-8510, 784122-01 |
CAN1 CAN2 CAN3 CAN4 LIN5 LIN6 |
4 CAN channels 2 LIN channels[2]2 The CAN connection is through the TRC-8543, and the LIN connection is through the TRC-8546. |
18 | J17 |
Field Diagnostic Tester
Use the field diagnostic tester (FDT) and maintenance software to perform continuity checks for components within the system. The FDT generates reports and alerts you of discontinuity and reasonable shorts within the system.
| Component Type | Model | Resource Name | NI Part Number |
|---|---|---|---|
| FDT | FDT-16050 | N/A | 789858-01 |
ETX-16400/16401 Environmental Characteristics
| Operating temperature | 5 °C to 32 °C |
|---|---|
| Storage temperature | 0 °C to 60 °C |
| Operating humidity | 10% RH to 80% RH, noncondensing |
| Storage humidity | 5% RH to 80% RH, noncondensing |
| Pollution degree | 2 |
| Maximum altitude | 2000 m |