Table 10. ETX-1630x Mass Interconnect Slot Number Assignment
Slot Number Equipment Description
J1 PXI-6528, PXI-2567 Adapter communication
J2 DC PDU DC power distribution
J3 Reserved
J4 PXIe-4082, PXIe-2737, PXIe-4139 Measurement I/O
J5 Reserved
J6 RMX-41041 Programmable power supply (PPS)
J7 Reserved
J8 High-voltage keepout
J9 EA-PS 11500-30[1]1 The ETX-16309 has a different power supply than the other ETX models. Refer to ETX-16309 specific supplemental documentation for more information. High-power PPS
J10 High-voltage keepout
J11 RM-16061 Pulse current output
J12 RM-16061 Pulse current output
J13 PXIe-2527, PXIe-4082 Measurement I/O (300 V)
J14 High-voltage keepout
J15 RM-26999 Voltage channels
J16 High-voltage keepout
J17 PXIe-4112, PXIe-6366, PXI-8510, PXIe-4322

Automotive Ethernet or FlexRay

PXI-8510: CAN/LIN

J18 RM-26999 Current transducer connections for the pulser and power signals DAQ
J19 Reserved
J20 Not used
J21 Not used
J22 Not used
J23 Not used
J24 Not used
J25 Not used
Note The ETX-1630x nomenclature adds J to the slot numbers on the mass interconnect.
Note You must ensure that the high-voltage keepout and slots are free of non-insulated conductors on the receiver side and the interface-test adapter side of the mass interconnect.