For environments with high shock and
vibration, NI recommends mounting the cRIO-906x directly on a
flat, rigid surface using the mounting holes in the device.
What to Use
cRIO-906x
Screwdriver, Phillips #2
M4 or number 8 screw (x2), user-provided, longer than 19.00 mm(0.75 in.) to pass all the way through the cRIO-906x
Note The cRIO-9063/64/65 have two mounting screws. The cRIO-9066/67/68 have three mounting
screws.
What to Do
Complete the following steps to mount the cRIO-906x directly
on a flat surface. Figure 25. cRIO-9063/9064/9065 Mounting Hole
Locations, Typical
Prepare the surface for mounting the cRIO-906x using the
Surface Mounting Dimensions.
Align the cRIO-906x on the surface.
Fasten the cRIO-906x to the surface using the M4 or
number 8 screws appropriate for the surface. Tighten the screws to a maximum torque of 1.3 N · m(11.5 lb · in.).