Product Descriptions
- Updated2022-05-02
- 6 minute(s) read
Product Descriptions
cRIO-9063: 667 MHz Dual-Core CPU, 256 MB DRAM, 512 MB Storage, Zynq-7020 FPGA, 4-Slot CompactRIO Controller
cRIO-9064: 667 MHz Dual-Core CPU, 512 MB DRAM, 1 GB Storage, and Zynq-7020 FPGA, 4-Slot CompactRIO Controller
cRIO-9065: 667 MHz Dual-Core CPU, 512 MB DRAM, 1 GB Storage, Zynq-7020 FPGA, Extended Temperature, 4-Slot CompactRIO Controller
cRIO-9066: 667 MHz Dual-Core CPU, 256 MB DRAM, 512 MB Storage, Zynq-7020 FPGA, 8-Slot CompactRIO Controller
cRIO-9067: 667 MHz Dual-Core CPU, 512 MB DRAM, 1 GB Storage, Zynq-7020 FPGA, 8-Slot CompactRIO Controller
cRIO-9068: 667 MHz Dual-Core CPU, 512 MB DRAM, 1 GB Storage, Zynq-7020 FPGA, Extended Temperature, 8-Slot CompactRIO Controller
Physical Characteristics
| |||||||||||||||
|
cRIO-9063/9064/9065/9066/9067 Power Connector
| |||||||||||||
|
cRIO-9068 Power Connector
| |||||||||||||
|
Environmental
| |||||||||||||||
Storage temperature | -40 °C to 85 °C |
Ingress protection | IP40 |
Operating humidity | 10% RH to 90% RH, noncondensing |
Storage humidity | 5% RH to 95% RH, noncondensing |
Pollution Degree | 2 |
Maximum altitude | 5,000 m |
Indoor use only.
Hazardous Locations
Explosive atmospheres rating | Ex ec IIC T4 Gc |
CCC certificate number | 2021312304000993 |
Safety Guidelines
Operate the product only as described in this document.
Safety Guidelines for Hazardous Locations
The cRIO-9063/9064/9066/9067 have been evaluated as Ex ec IIC T4 Gc equipment and are CCC certified. Each product is suitable for use within ambient temperatures of -20 °C ≤ Ta ≤55 °C in either nonhazardous locations or Zone 2 hazardous locations.
The cRIO-9065/9068 have been evaluated as Ex ec IIC T4 Gc equipment and are CCC certified. Each product is suitable for use within ambient temperatures of -40 °C ≤ Ta ≤70 °C in either nonhazardous locations or Zone 2 hazardous locations.
Follow these guidelines if you are installing the product in a potentially explosive environment. Not following these guidelines may result in serious injury or death.
Port | Required Accessory | Part Number |
---|---|---|
USB Device Port | NI Locking USB Cable | 157788‐01 |
USB Host Port | NI Industrial USB Extender Cable | 152166‐xx |
Safety Voltages
cRIO-9063, cRIO-9064, cRIO-9065, cRIO-9066, cRIO-9067
Connect only voltages that are within the following limits:
V terminal to C terminal | 30 V DC maximum, Measurement Category I |
cRIO-9068
Connect only voltages that are within the following limits:
V terminal to C terminal | 30 V maximum, Measurement Category I | ||||||
|
Power Requirements
Voltage input range | 9 V DC to 30 V DC | ||||||||
Reverse-voltage protection | 30 V DC maximum | ||||||||
|
Installing C Series Modules
Verify that power is not connected to the I/O connector(s) on the C Series module.
Removing C Series Modules
Verify that power is not connected to the I/O connector(s) on the C Series module before you remove a module from the chassis.
Safety Compliance and Hazardous Locations Standards
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
- IEC 61010-1
- IEC 60079-0, IEC 60079-7
- GB/T3836.1, GB/T3836.3
Product Certifications and Declarations
To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
Worldwide Support and Services
NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504, USA.