Testing Your Controller in MAX
- Updated2022-12-13
- 2 minute(s) read
Testing Your Controller in MAX
Complete the following steps to run a test panel in Measurement & Automation Explorer (MAX) to confirm that your cRIO-905x is communicating with your system.
Note MAX test panels are only available for
systems running NI-DAQmx driver software with supported C
Series modules installed, and with modules deployed in the Real-Time (NI-DAQmx)
programming mode. For additional information, refer to Installing Software on the Host Computer and Choosing Your Programming Mode.
- Launch MAX.
-
Locate and select your cRIO-905x system in the
My System tree. If your module and the software are functioning correctly, the System Settings for your module will show a status of
Connected - Running.
Note If your cRIO-905x has a single Ethernet port, only one Ethernet IP address is populated in the system settings.If your cRIO-905x is present but the status is Connected – Safe Mode (No Software Installed), complete the procedure to install software on the cRIO-905x in Installing Software on the Controller. - Wire the C Series module as indicated in the C Series module documentation.
-
Right-click any module and select
Test Panels, or select
Test Panels from the main configuration window options.
Note If the module you select is not deployed in Real-Time (NI-DAQmx) mode, you will be prompted to switch modes to view the test panel. -
Configure the measurement settings and click
Start.