Installing PXI Filler Panels

Install filler panels, either standard filler panels or EMC panels, over each slot of a PXI chassis that does not contain a module to ensure proper cooling.

Standard filler panels improve the cooling performance of the system; EMC filler panels contain additional gaskets to control EMC emissions from the chassis.

Note Filler panels must be installed over all chassis slots to ensure adequate cooling of modules. To ensure optimal cooling performance, NI recommends using slot blockers in conjunction with filler panels.
  1. Remove the captive screw covers, if present, from the filler panel.
  2. Secure the captive mounting screws to the chassis; for EMC filler panels, ensure that the EMC gasket is on the right side.
    Do not overtighten the screws (2.5 in. · lb maximum).
    Filler panel typeDiagram
    Standard filler panel
    Figure 1. Standard Filler Panel Installation

    1378

    EMC filler panel
    Figure 2. EMC Filler Panel Installation

    1378

    1. Captive screw covers
    2. Captive mounting screws
    3. EMC gasket

For more information about standard and EMC filler panels, visit ni.com/info and enter the info code emcpanels.